Management Agents Events Reference
Event DescriptionEvent
Severity
Event ID
Storage System Temperature Degraded.%nThe %6 %7 storage system connected to
SCSI bus %5 of the controller in slot %4 system has a temperature outside the normal
operating range.%n [SNMP TRAP: 8010 in CPQSTSYS.MIB]
Warning1077
Storage System Temperature OK.%nThe temperature in the %6 %7 storage system
connected to SCSI bus %5 of the controller in slot %4 has returned to the normal
operating range.%n [SNMP TRAP: 8011 in CPQSTSYS.MIB]
Informational1078
Storage System Side Panel Removed.%nThe side panel has been removed on the %6
%7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP
TRAP: 8013 in CPQSTSYS.MIB]
Warning1101
Storage System Side Panel In Place.%nThe side panel has been replaced on the %6
%7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP
TRAP: 8012 in CPQSTSYS.MIB]
Informational1102
Storage System Fault Tolerant Power Supply Degraded.%nThe fault tolerant power
supply in the %6 %7 storage system connected to SCSI bus %5 of the controller in
slot %4 has a degraded status. Restore power or replace any failed power supply.%n
[SNMP TRAP: 8015 in CPQSTSYS.MIB]
Warning1104
Storage System Fan Module Status Change. Storage system "%4" fan module at
location %5 has a new status of %6.%n(Fan module status values: 1=other,
2=notInstalled, 3=ok, 4=degraded, 5=failed)%n [SNMP TRAP: 8020 in CPQSTSYS.MIB]
Warning1152
Storage System Power Supply Status Change. Storage system "%4" power supply at
location %5 has a new status of %6.%n(Power supply status values: 1=other,
2=notInstalled, 3=ok, 4=failed, 5=degraded)%n [SNMP TRAP: 8021 in CPQSTSYS.MIB]
Warning1153
Storage System Power Supply UPS Status Change. The UPS attached to storage
system "%4" power supply bay %5 has a new status of %7.%n(Power supply UPS
status values: 1=other, 2=noUps, 3=ok, 4=powerFailed, 5=batteryLow)%n [SNMP
TRAP: 8018 in CPQSTSYS.MIB]
Warning1154
Storage System Temperature Sensor Status Change. Storage system "%4" temperature
sensor at location %5 has a new status of %6 and a current temperature value of %7
celsius.%n(Temperature sensor status values: 1=other, 2=ok,3=degraded, 4=failed)%n
[SNMP TRAP: 8019 in CPQSTSYS.MIB]
Warning1155
Storage System Fan Status Change. An enclosure attached to port %5 of storage
system "%4" has a new fan status of %7. The enclosure model is "%6". %n(Fan status
values: 1=other, 2=notInstalled, 3=ok, 4=degraded, 5=failed, 6=notSupported,
7=degraded-Fan1Failed, 8=degraded-Fan2Failed) %n [SNMP TRAP: 8022 in
CPQSTSYS.MIB]
Warning1188
Storage System Temperature Status Change. An enclosure attached to port %5 of
storage system "%4" has a new temperature status of %7. The enclosure model is
"%6". %n(Temperature status values: 1=other, 2=noTemp, 3=ok, 4=degraded, 5=failed)
%n [SNMP TRAP: 8023 in CPQSTSYS.MIB]
Warning1189
Storage System Power Supply Status Change. An enclosure attached to port %5 of
storage system "%4" has a new power supply status of %7. The enclosure model is
"%6". %n(Power supply status values: 1=other, 2=noFltTolPower, 3=ok, 4=degraded,
5=failed, 6=notSupported, 7=noFltTolPower-Bay1Missing,
8=noFltTolPower-Bay2Missing) %n [SNMP TRAP: 8024 in CPQSTSYS.MIB]
Warning1190
Storage System Recovery Server Option Status Change. Storage system "%4" has a
new RSO status of %5.%n(RSO status values: 1=other, 2=notSupported,
3=notConfigured, 4=disabled, 5=daemonDownDisabled, 6=ok, 7=daemonDownActive,
8=noSecondary, 9=daemonDownNoSecondary, 10=linkDown,
11=daemonDownLinkDown, 12=secondaryRunningAuto, 13=secondaryRunningUser,
14=evTimeoutError) %n [SNMP TRAP: 8025 in CPQSTSYS.MIB]
Warning1196
Storage System Fan Status Change.%nThe %6 %7 storage system connected to SCSI
bus %5 of the controller in %4 has a new status of %2.%n(Fan status values: 1=other,
2=ok, 3=failed, 4=notInstalled, 5=degraded)%n [SNMP TRAP: 8026 in CPQSTSYS.MIB]
Warning1212