Management Agents Events Reference

Event DescriptionEvent SeverityEvent ID
One of the temperature sensors crossed its upper non-critical threshold. Probable
Cause: The temperature inside the server has gone outside the factory specified range
for normal operation. You should quit applications and power down the server to
protect its hardware from damage. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Find cause of temperature
anomaly and fix it. SNMP Trap: hpTemperature - 755 in HPIFP02TRAP.MIB.Warning755
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Find cause of temperature
anomaly and fix it. SNMP Trap: hpTemperature - 756 in HPIFP02TRAP.MIB.Error756
The AC voltage to the power supply was lost or is out of range. Probable Cause: The
AC voltage was lost, or is the wrong range for the system. Recommended Action:
Verify the power supply is plugged in to the proper voltage for the system. SNMP
Trap: RedundantPower - 757 in HPIFP02TRAP.MIB.Warning757
The power supply AC voltage is out of range. Probable Cause: The AC voltage is
connected to the power supply, but it is not the voltage range required for the system.
Recommended Action: Connect the power supply to the proper voltage range. SNMP
Trap: RedundantPower - 758 in HPIFP02TRAP.MIB.Warning758
Invalid OS INIT checksum. Probable Cause: OS has registered a bad OS_INIT vector
or the data has been lost. Recommended Action: Reboot system to allow vector to
be re-registered. SNMP Trap: hpevtBadOsInitChecksum - 5001 in HPIFPTRAP.MIB.Warning5001
Bad OS MCA checksum. Probable Cause: OS has registered a bad OS_MCA vector
or the data has been lost. Recommended Action: Reboot system to allow vector to
be re-registered. SNMP Trap: hpevtBadOsMcaChecksum - 5002 in HPIFPTRAP.MIB.Warning5002
BMC interface to IPMI failed. Probable Cause: BMC firmware has locked up or the
BMC is disabled. Recommended Action: Cycle system power and attempt boot again.
If error re-occurs contact your HP representative for support. SNMP Trap:
hpevtBootBmcFailed - 5003 in HPIFPTRAP.MIB.Warning5003
Boot cell launch EFI failure. Probable Cause: The system has failed to launch EFI
because of an internal error. Recommended Action: Reboot or update System FW. If
problem persists contact your HP representative for support. SNMP Trap:
hpevtBootCellLaunchEfiFailure - 5010 in HPIFPTRAP.MIB.Error5010
Monarch selection failure. Probable Cause: An internal error has caused monarch
selection to fail. Recommended Action: Reboot. If problem persists contact your HP
representative for support. SNMP Trap: hpevtBootCellMonSelFailure - 5011 in
HPIFPTRAP.MIB.Error5011
CPU monarch collision. Probable Cause: Unexpected error has occurred during
monarch selection. Recommended Action: Reboot, if problem persists contact your
HP representative for support. SNMP Trap: hpevtBootCellMonarchCollision - 5013
in HPIFPTRAP.MIB.Warning5013
Boot cell virtualize EFI failure. Probable Cause: An internal error has occurred that
prevented EFI from virtualizing. Recommended Action: Reboot, if problem persists
contact your HP representative for support. SNMP Trap:
hpevtBootCellVirtualizeEfiFailure - 5023 in HPIFPTRAP.MIB.Error5023
Boot cell virtualize PAL failure. Probable Cause: SFW was unable to virtualize PAL.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. SNMP Trap: hpevtBootCellVirtualizePalFailure - 5025 in
HPIFPTRAP.MIB.Error5025
12 Management Agents Event Tables