Management Agents Events Reference
Event DescriptionEvent
Severity
Event ID
Drive Array Logical Drive Status Change. Logical drive number %5 on the array
controller in slot %4 has a new status of %2.%n(Logical Drive status values: 1=other,
2=ok, 3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding,
8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding,
13=notAvailable, 14=queuedForExpansion)%n [SNMP TRAP: 3008 in CPQIDA.MIB]
Error1062
Drive Array Spare Drive Status Change. The spare drive in slot %4, port %5, bay %6
has a new status of %2.%n(Spare status values: 1=other, 2=invalid, 3=failed, 4=inactive,
5=building, 6=active)%n [SNMP TRAP: 3017 in CPQIDA.MIB]
Error1063
Drive Array Physical Drive Status Change. The physical drive in slot %4, port %5,
bay %6 with serial number "%7", has a new status of %2.%n(Drive status values:
1=other, 2=ok, 3=failed, 4=predictiveFailure)%n[SNMP TRAP: 3029 in CPQIDA.MIB]
Error1064
Drive Array Accelerator Status Change. The array accelerator board attached to the
array controller in slot %4 has a new status of %2.%n(Accelerator status values:
1=other, 2=notConfigured, 3=enabled, 4=tmpDisabled, 5=permDisabled)%n [SNMP
TRAP: 3025 in CPQIDA.MIB]
Error1065
Drive Array Accelerator Bad Data. The array accelerator board attached to the array
controller in slot %4 is reporting that it contains bad cached data.%n[SNMP TRAP:
3026 in CPQIDA.MIB]
Error1066
Drive Array Accelerator Battery Failed. The array accelerator board attached to the
array controller in slot %4 is reporting a battery failure.%n[SNMP TRAP: 3027 in
CPQIDA.MIB]
Error1067
Drive Array Physical Drive Monitoring is not enabled. The physical drive in slot %4,
port %5, bay %6 with serial number "%7", does not have drive threshold monitoring
enabled.
Informational1098
Drive Array Controller Status Change. The Drive Array Controller in slot %4 has a
new status of %5.%n(Controller status values: 1=other, 2=ok, 3=generalFailure,
4=cableProblem, 5=poweredOff)%n [SNMP TRAP: 3028 in CPQIDA.MIB]
Warning1164
Drive Array Controller Active. The Drive Array Controller in slot %4 has become
the active controller.%n [SNMP TRAP: 3016 in CPQIDA.MIB]
Warning1165
Drive Array Tape Library Status Change. The tape library in slot %4, SCSI bus %5,
SCSI target %6 has a new status of %7.%n(Library status values: 1=other, 2=ok,
3=degraded, 4=failed, 5=offline)%n [SNMP TRAP: 3031 in CPQIDA.MIB]
Warning1180
Drive Array Tape Library Door Status Change. The tape library in slot %4, SCSI bus
%5, SCSI target %6 has a new door status of %7.%n(Library door status values:
1=other, 2=notSupported, 3=closed, 4=open)%n [SNMP TRAP: 3021 in CPQIDA.MIB]
Warning1181
Drive Array Tape Drive Status Change. The tape drive in slot %4, SCSI bus %5, SCSI
target %6 has a new status of %7.%n(Tape drive status values: 1=other, 2=ok,
3=degraded, 4=failed, 5=offline, 6=missingWasOk, 7=missingWasOffline)%n [SNMP
TRAP: 3032 in CPQIDA.MIB]
Warning1182
Drive Array Tape Drive Cleaning Required. The tape drive in slot %4, SCSI bus %5,
SCSI target %6 requires cleaning.%n [SNMP TRAP: 3023 in CPQIDA.MIB]
Warning1183
Drive Array Tape Drive Replace Cleaning Tape. The cleaning tape in the tape drive
in slot %4, SCSI bus %5, SCSI target %6 needs to be replaced.%n [SNMP TRAP: 3024
in CPQIDA.MIB]
Warning1184
Drive Array Controller Status Change. The Drive Array Controller in %7 has a new
status of %5.%n(Controller status values: 1=other, 2=ok, 3=generalFailure,
4=cableProblem, 5=poweredOff)%n [SNMP TRAP: 3033 in CPQIDA.MIB]
Warning1199
Drive Array Logical Drive Status Change. Logical drive number %5 on the array
controller in %4 has a new status of %2.%n(Logical Drive status values: 1=other, 2=ok,
3=failed, 4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding,
8=wrongDrive, 9=badConnect, 10=overheating, 11=shutdown, 12=expanding,
13=notAvailable, 14=queuedForExpansion)%n [SNMP TRAP: 3034 in CPQIDA.MIB]
Warning1200
Storage Agent Events 117