Installation (Smart Setup) Guide, Windows Server 2003, v6.2
NOTE: If you are installing an HPVM Windows guest, you do not need to run EBSU as part
of your setup. Skip this section and go to the next section: “Run Windows Setup” (page 34).
To run EBSU, complete the following steps:
1. Power on the server. The server boots to EFI.
You can use the EFI Boot Manager from the Enhanced interface (grey background) or the
Legacy interface (black background).
2. Load the HP Smart Setup media into the server DVD drive.
3. From the EFI Boot Menu, select Internal Bootable DVD and press Enter. EBSU starts and
displays the Welcome screen.
Figure 2-7 Enter EBSU
4. Click OK and press Enter
5. From the Main Menu, select Express Setup and press Enter.
Figure 2-8 Select Express Setup
6. EBSU displays the Express Setup introduction. Press Enter to continue.
7. EBSU displays the firmware update screen, listing each device, its installed firmware version,
and the firmware version on the Smart Setup media. Select the firmware devices you want
to update. To continue, select Next and press Enter.