Command causes machine check abort
Issue
A machine check abort (MCA) can occur when the reconnect -r command
is issued for a Smart Array SA640x with firmware version 2.74 when the server
contains multiple SA640x cards with different firmware versions.
Servers Superdome SX2000, rx8640, rx7640
Workaround HP recommends you maintain the same firmware version for all Smart Array
cards on a server.
System Management Homepage (SMH)
Components flagged with red exclamation mark
Issue
When running the setup.exe command without having System Management
Homepage (SMH) installed on the system, some configurable components might
show up with a red exclamation mark (!) when viewed in the All
Configurable Components category of the HP Remote Deployment Utility
main window. A pop-up window with the following message might also be
displayed:
One or more components that have been selected for installation require configuration but
are not configured. For the best results, it is recommended that you configure the components
before installation.
Servers All Integrity
Workaround To make the red exclamation mark go away, copy the System Management
Homepage component to a writable location and then configure it.
Some components not shown
Issue The 5.1 version of Management Agents does not show the following components
under Version Control:
HP Storage Works Event Notification Driver for Ultra320 SCSI devices for
Windows Server 2003 on Itanium-based systems (CP006112, printss.sys)
HP Ultra 160 SCSI Controller Driver for Windows Server 2003 on
Itanium-based systems (CP006358, sym_u3.sys)
HP Array Diagnostic Utility for Windows Server 2003 on Itanium-based
systems (CP006361, Hpadu.exe)
HP StorageWorks FC-HBA Configuration Utilities by Emulex for Windows
Server 2003 Itanium-based systems (CP006084, HBAnyware.exe)
HP StorageWorks FC-HBA Configuration Utilities by QLogic for Windows
Server 2003 Itanium-based systems (CP005831, SANSurferVer.exe)
Servers All Integrity
Workaround Access the component versions manually from the Support Pack, HP Smart
Setup CD, or by similar methods.
Another solution is to use https://127.0.0.1:2381 instead of
https://localhost:2381.
SMH fails to open
Issue If Internet Explorer is configured to browse through a proxy server and the
Bypass proxy server for local addresses checkbox is not selected, attempting
to connect to the local SMH (https://localhost:2381) fails with a Page
cannot be displayed error.
Servers All Integrity
Workaround Configure Internet Explorer to bypass the proxy server for local addresses as
follows: