HP Integrity Servers with Microsoft Windows Server 2003 Release Notes v6.1

1. Uninstall the Storport driver after using the Microsoft reinstall media or
clear the Emulex Storport driver checkbox during the Support
Pack update from the HP Smart Setup CD.
2. Install the SCSIPort driver using the Smart Component in the Others
directory on the HP Smart Setup CD. This driver is also available for
download at http://www.hp.com/.
MSA fails with Storport driver installed
Issue MSA flash utility version 6.86.1.52 used on Active-Active MSA Controllers, and
version 5.10.1.52 used on Active-Passive Controllers will fail to run when the
latest Storport driver (KB916048) is installed.
Servers All Integrity
Workaround Use the MSA Flash utility with the fix that is available on the HP website at the
following location:
http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?lang=en&cc=us&
prodNameId=415600&prodTypeId=12169&prodSeriesId=415598&swLang=13&swEnvOID=1060
LUNs undetected by ACU
Issue The ACU does not detect any LUNs attached to an AB379A or AB429A HBA
that has been swapped or added using the Online Add/Replace function while
the ACU was running.
Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600
Workaround Stopping and restarting the ACU corrects this issue. The ACU then sees the
LUNs attached to the AB379A or AB429A HBAs.
HBA removal fails
Issue When attempting to remove the AB379A or AB429A HBA using the Online
Replace functionality, a message appears:
The device Qlogic Fibre Channel Adapter cannot be
stopped because a program is still accessing it.
Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600
Workaround 1. Stop the QLogic Management Suite Java Agent in the Services window
under Computer Management.
2. Stop the AB379A or AB429A using the Safely Remove Hardware function.
HPSUM hangs on MSA 1500 boot
Issue HP Smart Update Manager (HP-SUM) hangs when an MSA 1500 connected to
QLogic boots.
Servers All Integrity
Workaround This is an MSA firmware problem. There is no workaround at this time. New
firmware is expected in January 2008.
Hard Disk Configuration
Disk configuration lost after reboot
Issue When configuring a boot LUN in EBSU Express Install using a direct connect
configuration to an MSA1000, the storage hard disk device configuration may
be lost after rebooting the system.
Servers All Integrity
24 Release 6.1 Overview