HP Integrity Servers with Microsoft Windows Server 2003 Release Notes v5.5
Servers All Integrity
Workaround Ignore these events, as they do not cause any problems or loss of data. There is
no fix at this time.
StorageWorks 43xx enclosures may cause errors
Issue
StorageWorks 43xx enclosures in a dual bus configuration with an Ultra3 Dual
Bus I/O Module and a single power supply might report errors and fail the
logical volumes when attached to Smart Array Controllers. Port A of the
StorageWorks 44xx enclosure might intermittently report that all drives installed
in the lower bays (Port A, bays 1-7) have been hot-plug replaced even though
the drives were not replaced.
As a result, the array controller may fail the logical volumes, causing the data
to become inaccessible. If the operating system is running from those drives,
the server might hang or display a blue screen. When the server is rebooted,
the drives appear to be working properly; however, some data might be
inaccessible. A Power-On Self-Test (POST) error message is not displayed. The
problem occurs regardless of the position of the power supply or fans in the
enclosure. This affects any StorageWorks Enclosure Model 4314R, Model 4314T,
or Model 4354R in a dual bus configuration with an Ultra3 Dual Bus I/O Module
and a single power supply, attached to either Smart Array 5302 or Smart Array
5304 Controller.
Servers All Integrity
Workaround Operate the StorageWorks enclosures with a minimum of two power supplies.
Configuration utility may be inaccessible
Issue
The Smart-Array Option ROM Configuration for Arrays Utility menu of the
Smart Array controller in the root cell I/O chassis (core I/O chassis) might not
be accessed when the F8 key is pressed on the USB keyboard during system
boot. This problem only occurs if you are configuring the Smart Array using
the USB keyboard connected to the HP Graphics and USB card. The serial
console from the MP should work fine.
Servers All Integrity
Workaround Do the following:
1. Boot the system to the EFI shell.
2. At the EFI prompt, enter the following: search core cell. For example,
enter search 0 if the core cell is 0.
3. When you see the Smart-Array Option ROM Configuration for Arrays
Utility menu, press the F8 key on the USB keyboard.
4. Now you should see the Smart-Array Option ROM Configuration for
Arrays Utility menu.
Tools menu radio buttons inactive
Issue When viewing the driver properties in the device manager for the Smart Array
6400 Controller, an enhanced Tools menu bar displays. This bar provides radio
buttons for launching the ACU and HP Insight Storage Agents. However, these
buttons do not work in this release of the driver.
Servers All Integrity
34 Release 5.5 Overview