HP Integrity Servers with Microsoft Windows Server 2003 Release Notes v5.5

Fibre Channel
Installation causes MSA 1500 driver to be flagged
Issue
A yellow exclamation mark (!) might be displayed for the HP StorageWorks
1000/ MSA 1500 event notification driver after installing the Windows Server
2003 SP2 operating system using the 5.2 release reinstall media.
Servers All Integrity
Workaround Using the Release 5.2 HP Smart Setup Media (SSM) CD, do one of the following:
Install the Support Pack (recommended).
Install HP StorageWorks MSA1000/MSA1500 Event Notification Driver
component.
Support Pack update generates errors
Issue When updating a system using the Support Pack from the HP Smart Setup 5.1
CD, errors may be reported in the Windows application event log. The indicated
source is Emulex HBAnyware.
Servers All Integrity
Workaround Ignore these error messages. The Support Pack first installs the new SCSIPort
or STORPort driver, and then updates HBAnyware. The new drivers are not
compatible with the previous revision of HBAnyware, causing the event log
errors. After the new version of HBAnyware is installed, this issue is resolved.
Inapplicable errors seen in kit update
Issue When updating the HP StorageWorks Fibre Channel Adapter Kit for the Emulex
Storport driver, the following error message might be displayed in a pop-up
window:
Windows cannot find 'C:\Program'. Make sure you typed the name
correctly, then try again. To search for a file, click the Start
button, then click Search
Servers All Integrity
Workaround You can ignore this error message. The Support Pack first installs the new
SCSIPort or STORPort driver, and then updates HBAnyware. The new drivers
are not compatible with the previous revision of HBAnyware, causing the event
log errors. After the new version of HBAnyware is installed, this issue is
resolved.
Redundant entries seen in the Add/Remove Program
Issue The Add/Remove Program contains two entries after upgrading the HP
StorageWorks FC-HBA Configuration Utilities by QLogic for Windows Server
2003 Itanium-based systems from revision 2.0.30.78 to revision 5.0.0.4.
Servers All Integrity
Workaround Uninstall HP StorageWorks FC-HBA Configuration Utilities by QLogic for
Windows Server 2003 Itanium-based systems revision 2.0.30.78 before installing
revision 5.0.0.4.
Emulex HBAs use different driver
Issue After performing an operating system installation using Microsoft reinstall
media or updating an existing installation using the Support Pack from the HP
Smart Setup CD, the Emulex HBAs now use the STORPORT driver instead of
the SCSIPort driver previously used.
Servers All Integrity
Troubleshooting Common Issues 27