Mellanox MLNX-OS® User Manualfor SX1018HP Ethernet Managed Blade Switch
Rev 1.6.9
Mellanox Technologies
50
Mellanox Technologies Confidential
4.6.1 Supported Events
The following table presents the supported events and maps them to their relevant MIB OID.
Table 22 - Supported Event Notifications and MIB Mapping
Event Name Event Description MIB OID Comments
asic-chip-down ASIC (chip) down Mellanox-EFM-MIB:
asicChipDown
Not supported
cpu-util-high CPU utilization has risen
too high
Mellanox-EFM-MIB:
cpuUtilHigh
disk-space-low File system free space has
fallen too low
Mellanox-EFM-MIB:
diskSpaceLow
health-module-status Health module status
changed
Mellanox-EFM-MIB:
systemHealthStatus
insufficient-fans Insufficient amount of fans
in system
Mellanox-EFM-MIB:
insufficientFans
insufficient-fans-recover Insufficient amount of fans
in system recovered
Mellanox-EFM-MIB:
insufficientFansRecover
insufficient-power Insufficient power supply Mellanox-EFM-MIB:
insufficientPower
interface-down An interface’s link state
has changed to DOWN
RFC1213: linkdown
(SNMPv1)
Supported for
Ethernet, InfiniBand
and management
interfaces for 1U
and blade systems
interface-up An interface’s link state
has changed to UP
RFC1213: linkup
(SNMPv1)
Supported for
Ethernet, InfiniBand
and management
interfaces for 1U
and blade systems.
internal-bus-error
Internal bus (I
2
C) error
Mellanox-EFM-MIB:
internalBusError
liveness-failure A process in the system is
detected as hung
Not implemented
low-power Low power supply Mellanox-EFM-MIB:
lowPower
low-power-recover Low power supply recover Mellanox-EFM-MIB:
lowPowerRecover
new_root Local bridge became a
root bridge
Bridge-MIB:
newRoot
Supported for
Ethernet
paging-high Paging activity has risen
too high
N/A Not supported