Reference Guide
HPMA Audit Message Reference
60
HP Medical Archive
When an unknown or unexpected file is detected in the object store
and moved to the “garbage” directory, this message is issued.
The “SVRU - Object Store Verify Unknown” audit message should be moni-
tored closely. It means unexpected files were detected in the object store. This
situation should be investigated immediately to determine how the files were
created, as it can indicate attempts to tamper with content or impending
hardware failures.
SYSD—Node Stop
When an HP Medical Archive grid service is stopped gracefully, this
message is generated to indicate the shutdown was requested.
The message does not indicate if the host server is being stopped, only
the reporting service.
SYSU—Node Start
When an HP Medical Archive grid service is started, this message is
generated and indicates if the previous shutdown was clean (com-
manded) or disorderly (unexpected).
Table 59: SVRU—Object Store Verify Unknown Fields
Code Field Description
FPTH File Path The full path to the unexpected file’s original location.
Table 60: SYSD—Node Stop Fields
Code Field Description
RSLT Clean Shutdown The nature of the shutdown:
SUCS—System was cleanly shutdown.
Table 61: SYSU—Node Start Fields
Code Field Description
RSLT Clean Shutdown The nature of the shutdown:
SUCS—System was cleanly shutdown.
DSDN—System was not cleanly shutdown.