Reference Guide
HPMA Audit Message Reference
42
HP Medical Archive
FSTG—File Store to Grid
When new content is stored via the FSG, the content is cached locally
by the FSG server and is copied into the grid. When the grid confirms
it has stored the copy (and is processing it under its business rules for
replication), this message is issued.
If a failure is logged, the FSG initiates a new storage attempt. Retries
continue until successful.
FSWI—File Swap In
A file has been retrieved from the grid for storage in the FSG local
cache. Content still resides in the grid.
Table 36: FSTG—File Store to Grid Fields
Code Field Description
FPTH File path The complete path and name of the file being stored.
FLTP File Type Indicates the type of object storage, as processed by the
grid’s file type detection.
UUID Universal Unique
ID
The identifier of the file content within the grid.
RSLT Result Code The result of the storage operation:
SUCS—Successfully stored.
FTER—Failed extended type verification (will be re-
ingested as a generic object).
TOUT—Failed due to timeout.
ERRC—Failed due to lost connection.
GERR—A general error occurred while storing content.
Table 37: FSWI—File Swap In Fields
Code Field Description
FPTH File path The complete path and name of the file added to the FSG
local cache.
UUID Universal Unique
ID
The identifier of the file content within the grid.