McDATA 4Gb SAN Switch for HP p-Class BladeSystem release notes (AA-RW1ZH-TE, April 2008)

Fabric binding enablement status inconsistent
When fabric binding was enabled from HAFM, the C LI would report it as enabled, but Element Manager
and McDATA Web Se
rver report it as disabled.
Nameserver GID_A failing
GID_A now returns data instead of being rejected if Domain scope is 0.
Inconsistency with McDATA Web Server menu displays
View menu is now always displayed before the wizards menu.
Ability to add additional McDATA Web Server session
User will not be promp ted to add a second fabric on start of McDATA Web Server if system is executing
a
CPU-intensive program.
The alarm log can ll and be lost with fabric login failure
When multiple M cDATA Web Ser vers are pointed at a fabric and one of the sessions is used to change
the
password, the alarm log is no longer lled with login failures every second.
Accounting RADIUS server not validated
The a cc ounting RADIUS servers are now validated when a new McDATA Web Server session is initiated.
N_Ports taken ofine
Implicit har
d
zoning is enabled by default eliminating the need to take N_Ports ofine while converting
soft zoning
to
ACL hard zoning.
E_Port status not displaying correctly
E_Ports are now shown as segmented or isolated if the E_Port does not complete initialization.
GUI Switch tab do esn't display all info
The GUI Switch tab now displays all switch information when each switch's column is expanded.
No error message on out of range domain ID
Domain ID range is now validated by the CLI.
Nameserver info does not always update
Nameserver information in the Devices tab now updates correctly after changes in the fabric.
Port counters display incorrect information
Port statistics counters now display correct information after changing the port type of a port from loo p
to
non-loop.
No error or success message on zoning cancel
An error or success message is now seen after activating a large zo ne set or security set and then
canceli
ng the
operation.
6