McDATA 4Gb SAN Switch for HP p-Class BladeSystem release notes (AA-RW1ZH-TE, April 2008)

Workaround
UseElement Managerto see stateofswitchbinding.
Fabric binding activation fails in Open/Standard interoperabilit y mode
If you try to activate fabric binding in a fabric in Open/Standard Interoperability Mode with an HP
M-Series or McDATA switch other than a McDATA 4Gb SAN Switch, fabric bin ding activation will fail if
being activated from the CLI or Element Manager.
Workaround
Activate fabric binding from EFCM/HAFM.
EFCM/HAFM issues with zone names created using McDATA Web Server
EFCM/HAFM do es not treat zone names as case sensitive.
Workaround
When using bo
th
EFCM/HAFM and McDATA Web Server to modify zoning, do not use zone names
that
differ o
nlybylower/upper case.
Determining the current rmwar e version
This section describes how to determine the current version of rmware for the McDAT A 4Gb S AN S w itch.
Using HAFM
To determine the current version of rmware using HAFM:
1. Open the Element Manager for the McDATA 4Gb SAN Switch.
2. Select the Switch tab at the bottom of the Element Manager window.
•For rmware version 5.2.15. 00, the rmware version appears in this dia log.
For rmware version 6.4.0.06.00 or later, click the Firmware button on theleftsideofthe
display.
The rmware version appears in this dialog.
Using McDATA Web Server
To determine the current version of rmware using McDATA Web Server, log in to McDATA 4Gb SAN
Switch through a web browser using the switch IP address.
For rmware version 5.2.15. 00: Right-click the switch graphic in the topology display and select
Switch Properties.The rmware version appears in the dialog.
For rmware version 6.4.0. 06 .00 or later, do the following:
1. Select th e Switch tab at the bottom of the faceplate display.
2. Click the Firmware button on theleftsideofthe display. The rmware version appears
in this
data window.
Using the CLI
To determine the current version of rmware usingthe CLI, loginto the McDATA 4GbSAN Switch
throu
gh a
Telnet session using the switch IP address. Enter the Show Version command to display
the
r
mware version.
McDATA 4Gb SAN Switch for HP p-Class BladeSystem release notes
13