McDATA® 4Gb SAN Switch for HP p-Class BladeSystem Installation Guide (AA-RW1XC-TE, November 2006)

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem installation guide 55
Factory RADIUS configuration
The Show Setup Radius command displays RADIUS configuration values.
Factory switch service configuration
The Show Setup Services command displays switch service configuration values.
Table 17 Factory RADIUS configuration
Parameter Default
DeviceAuthOrder Local
UserAuthOrder Local
TotalServers 0
DeviceAuthServer False
UserAuthServer False
AccountingServer False
ServerIPAddress 10.0.0.1
ServerUDPPort 1812
Timeout 2 seconds
Retries 0
SignPackets False
Table 18 Factory switch service configuration
Parameter Default
TelnetEnabled True
SSHEnabled False
GUIMgmtEnabled True
SSLMgmtEnabled False
EmbeddedGUIEnabled True
SNMPEnabled True
NTPEnabled False
CIMEnabled True
FTPEnabled True
MgmtServerEnabled True