McDATA® 4Gb SAN Switch for HP p-Class BladeSystem Command Line Interface Guide (AA-RWEJA-TE, November 2006)

McDATA® 4Gb SAN Switch for HP p-Class BladeSystem command line interface guide 31
Security configuration parameters
Enter the Show Config Security command to display security configuration and port binding
parameters. These parameters determine how security is applied to the switch. See Table 20 for a
description of the switch security configuration parameters. See Table 21 for a description of the port
binding parameters.
McDATA4GbSAN #> show config security
Configuration Name: default
-------------------
Switch Security Configuration Information
-----------------------------------------
FabricBindingEnabled False
AutoSave True
Port Binding Status WWN
---- -------------- ---
0 False 10:00:08:00:88:04:73:75
9 False No port binding entries found.
1 False No port binding entries found.
2 False No port binding entries found.
3 False No port binding entries found.
4 False No port binding entries found.
5 False No port binding entries found.
6 False No port binding entries found.
7 False No port binding entries found.
8 False No port binding entries found.
Switch Binding Status WWN
--------------------- ---
Enabled - Fports 10:00:00:00:c9:4d:27:17
50:05:08:b2:00:b5:d2:73
50:05:08:b2:00:b5:db:33
50:05:08:b2:00:b6:3f:93
50:05:08:b2:00:7b:a7:e3
50:05:08:b2:00:7c:5b:93
10:00:08:00:88:04:73:75
See the ”Show Config Security command” on page 178.