McDATA® 4Gb SAN Switch for HP p-Class BladeSystem Command Line Interface Guide (AA-RWEJA-TE, November 2006)
McDATA® 4Gb SAN Switch for HP p-Class BladeSystem command line interface guide 199
Link Failures Number of optical link failures detected by this port. A link failure is a
loss of synchronization or a loss of signal while not in the offline state. A
loss of signal causes the switch to attempt to re-establish the link. If the
link is not re-established, a link failure is counted. A link reset is
performed after a link failure.
Login Number of device logins
Logout Number of device logouts
LongFramesIn Number of incidents of receiving one or more frames that are greater
than the maximum allowable size.
LoopTimeouts Number of loop timeouts
LossOfSync Number of synchronization losses (>100 ms) detected by this port. A loss
of synchronization is detected by receipt of an invalid transmission word.
LostFrames Number of incidents of lost frames
LostRRDYs Number of incidents of lost R_RDYs
PrimSeqErrors Number of primitive sequence errors detected
RxLinkResets Number of link reset primitives received from an attached device
RxOfflineSeq Number of offline sequences received
ShortFramesIn Number of incidents when one or more frames that are less than the
minimum size were received
TotalErrors Total number of errors detected
TotalLinkResets Total number of link resets
TotalLIPsRecvd Total number of LIPs received by this port
TotalLIPsXmitd Total number of LIPs transmitted by this port
TotalOfflineSeq Total number of offline sequences issued and received by this port
TotalRxFrames Total number of frames received by this port
TotalRxWords Total number of words received by this port
TotalTxFrames Total number of frames issued by this port
TotalTxWords Total number of words issued by this port
TxLinkResets Total number of link resets issued by this port
TxOfflineSeq Total number of offline sequences issued by this port
Table 32 Port activity data (Continued)
Entry Description