McDATA® 4Gb SAN Switch for HP p-Class BladeSystem Command Line Interface Guide (AA-RWEJA-TE, November 2006)

160
Notes In addition to critical, warn, and informative severity levels, the highest event severity level is alarm.
The alarm level describes events that are disruptive to the administration or operation of a fabric and
require administrator intervention. Alarms are always logged and always displayed on the screen.
Examples The following example configures the event log to record switch management events with warning
and critical severity levels associated with ports 0–3:
McDATA4GbSAN (admin) #> set log component switch
McDATA4GbSAN (admin) #> set log level warn
McDATA4GbSAN (admin) #> set log port 0 1 2 3
McDATA4GbSAN (admin) #> set log save
See also Set Alarm command, page 144
Show Log command, page 186