FW 6.4.0.06.00 McDATA 4Gb SAN Switch for HP p-Class BladeSystem Release Notes (AA-RW1ZD-TE, November 2006)
Nameserver GID_A failing
GID_A now returns data instead of being rejected if Domain scope is 0.
Inconsistency with McDATA Web Server menu displays
View menu is now always displayed before the wizards menu.
Ability to add additional McDATA Web Server session
User will not b
e prompted to add a second fabric on start of McDATA Web Server if system is executing a
CPU-intensive program.
The alarm log can fill and be lost with fabric login failure
When multiple McDATA Web Servers are pointed at a fabric and one of the sessions is used to change
the password, the alarm log is no longer filled with login failures every second.
Accounting RADIUS server not validated
The accounting RADIUS servers are now validated when a new McDATA Web Server session is initiated.
N_Ports taken offline
Implicit hard zoning is enabled by default eliminating the need to take N_Ports offline while converting
soft zoning to ACL hard zoning.
E_Port sta
tus not displaying correctly
E_Ports ar
e now shown as segmented or isolated if the E_Port does not complete initialization.
GUI Switch tab doesn’t display all info
The GUI Switch tab now displays all switch information when each switch’s column is expanded.
No error message on out of range domain ID
Domain ID
range is now validated by the CLI.
Nameserver info does not always update
Nameserver information in the Devices tab now updates correctly after changes in the fabric.
Port counters display incorrect information
Port statistics counters now display correct information after changing the port type of a port from loop
to non-loop.
No error or success message on zoning cancel
An error or success message is now seen after activating a large zone set or security set and then
canceling the operation.
6