NOTE: The actual steps will vary depending on your version of Linux.
1. Using the BIOS Setup Utility, verify your system configuration by choosing one of these
options based on your server model:
On ML110 G6 and DL120 G6 servers, verify the following settings:
Console Redirection
BIOS Serial console—Enabled
Baud Rate-9600
I/O Device Configuration
Embedded Serial Port Mode—BMC
Embedded Serial Port—Enabled
On ML150 G6 servers, verify the following settings:
Console Redirection
BIOS Serial console—Enabled
EMC Support (SPCR)—Enabled
Serial Port Mode—9600 8,n,1
Console Type—VT100
Continue C.R. after POST—On
I/O Device Configuration
Serial Port A—Enabled
Base I/O address—3F8
Interrupt—IRQ 4
On DL160 G6, DL160se G6, DL170h G6, DL180 G6, SL160z G6, SL170z G6, and SL2x170z
G6 servers, and SL165z G7 servers, verify the following settings:
Remote Access Configuration
Remote Access—Enabled
EMS support(SPCR)—Enabled
Terminal Type—VT100
Flow Control—None
Redirection after BIOS POST—Always
SuperIO Configuration
Serial Port Address—3F8
Serial Port IRQ—IRQ 4
2. In the /boot/grub/menu.lst file, append the following to the kernel startup line:
console=ttyS0 115200
Comment out the line
GRAPHICAL DISPLAY LINE
# splashimage=(hd0,0)/grub/splash.xpm.gz
3. Add an entry to allow serial console login in /etc/inittab. For example:
S0:12345:respawn:/sbin/agetty -L 115200 ttyS0 vt102
4. In /etc/securetty enable root access to ttyS0 by adding ttyS0.
5. In /etc/sysconfig/kudzu, set kudzu to not perform serial port probing during boot.
For example: