Installation guide
Chapter 10 Configuring the HP NetServer
127
5. Shut down the operating system and power down the HP NetServer.
Refer to Chapter 2, "Controls, Ports, and Indicators."
6. Set switch 5 from ON to OFF on the system board’s configuration switch.
7. Replace the cover and power up the HP NetServer.
Refer to Chapter 3, "Opening and Closing the HP NetServer."
Run Symbios Configuration Utility
NOTE Run the Symbios Configuration utility to do the following:
• To verify that devices on SCSI channels A and B are
displayed on the boot screen.
• To verify that the controllers of SCSI channels A and B are
set "On" to operate.
• To verify that both SCSI channels A and B are searched
for a bootable drive.
• To control the order in which SCSI channels A and B are
searched for a bootable drive.
Do the following to run the Symbios Configuration utility:
1. Restart the HP NetServer.
If you receive an error message during the boot process, refer to Chapter
12, "Troubleshooting," or the online help. Some power-up (boot) messages
are routine.
2. As soon as you see the message
Press Ctrl-C to start Symbios Configuration
Utility...
on the display monitor, press the Ctrl+C keys.