Technical information
163
For the latest product & technical information, refer to the Information Sources on pages 2 and 3.Updated 10/02/01
FIBRE ARRAY SOLUTIONS
• Dual high-performance, RAID controller cards-supports up to
100MB/sec data transfer rate per controller.
• Two 175W auto-ranging, hot-swap, redundant power supplies.
• Attach directly to FAStT Host Adapter(s) (P/N 00N6881) with short-
wave cables and GBICs or indirectly through SAN Fibre Channel
Managed Hub (P/N 35341RU) using cables from cable group D or E
with corresponding GBICs.
• Height is 4U (1U = 1.75in or 44.45mm)
• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity
Rack, Netfinity NetBAY22 or 19-inch EIA-D Industry-Standard Rack.
Mounting rails are included with the controller.
• For optimum performance no more than two FAStT500 Storage
Servers (P/N 35521RU) should be attached to a single hub (P/N
35341RU)
• Includes four FAStT500 Mini Hubs (P/N 00N6882), two for host and
two for storage.
• FAStT500 256MB Cache (P/N 00N6883) expansion is required in
installations where a large number of devices are supported.
• All connections to FAStT500 Mini Hubs require the use of GBICs.
GBICs not included.
Mini Hub
Mini Hub
Expansion Bays for
Additional Mini Hubs
Power Supplies
GBIC Ports
GBIC Ports
FAStT500 Storage Server
35521RU
GBIC
GBIC Ports
Netfinity FAStT500 Mini Hub
00N6882
• Provides additional connections to the Netfinity FAStT500
Storage Server - supports complex clustering or advanced
storage applications.
• All connections to FAStT500 Mini Hubs require the use of
GBICs. GBICs are not included.
Netfinity FAStT Host Adapter
00N6881
• PCI to FCAL 64/32-bit host adapter.
• Supported Attachments (use cable group D):
FAStT500 Storage Server
• Integrated short-wave optical port. No GBICs required.
• Full Fibre Channel Fabric support.
Netfinity FAStT
Host Adapter
• Contains a single integrated short-wave optical port (use cable group
D) and six female 0.8mm Very High Density Connection Interface (VHDCI)
SCSI connectors.
• Hot-Swap Redundant Fans and Power Supplies.
• Optional Netfinity Fibre Channel Failsafe RAID Controller (P/N 01K7296)
provides a redundant RAID controller and second Short-Wave Fibre
Connection (use cable group D).
• Attach directly to FAStT Host Adapter(s) (P/N 00N6881) or indirectly
through SAN Fibre Channel Managed Hub (P/N 35341RU) using cables
from cable group D.
• Height is 4U (1U =1.75in or 44.45mm).
• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity Rack,
Netfinity NetBAY22 or 19in EIA-D Industry-Standard Rack. Mounting rails
are included with the controller.
• For optimum performance no more than two RAID controller units (P/N
35261RU) should be attached to a single hub.
Standard Fibre Channel
RAID Controller
Netfinity Fibre Channel
Failsafe RAID Controller Opt
(P/N 01K7296)
Netfinity Fibre Channel RAID Controller
(35261RU)
FAStT200 Storage Server 35421RU
• Contains a single hot-plug, RAID controller which provides a single
host Fibre Channel arbitrated loop and a single storage Fibre Channel
arbitrated loop.
• Can be upgraded to a FAStT200 HA Storage Server through the
addition of a FAStT200 Redundant RAID Controller (P/N 19K1121).
• Integrated 10/100Mbps Ethernet connector and RS-232 service
support port.
• Performance optimized for 30 HDDs - supports optional FAStT
EXP500 Storage Expansion Units (P/N 35601RU).
• Two hot-swap 350W auto-ranging, redundant power supplies.
• Redundant fans - two hot-swap, dual-fan units.
• LED indicators on all critical components warn of faults,
over-temperature, and other abnormalities.
• Ten drive bays - supports slim-high or half-high Fibre Channel hot-
swap HDDs.
• Height is 3U (1U=1.75in or 44.45mm.
• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity
Rack, Netfinity NetBAY22 or 19in EIA-D industry standard rack.
Mounting rails are included with the controller.
• Supports long- and short-wave connections. Requires optional
GBICs for each connection. GBICs not included.
Hot-swap Fan
Hot-swap Power
Supplies
Hot-swap Fan
GBIC Port
GBIC Port
10/100 Ethernet Port
RS-232
Hot-swap Fan
Hot-swap Power
Hot-swap Fan
GBIC Port
GBIC Port
10/100 Ethernet Port
RS-232
• Contains two hot-plug, RAID controllers. Each controller provides a
single host Fibre Channel arbitrated loop and a single storage Fibre
Channel arbitrated loop.
• Integrated 10/100Mbps Ethernet connector and RS-232 service
support port.
• Performance optimized for 30 HDDs-- supports optional FAStT
EXP500 Storage Expansion Units (P/N 35601RU).
• Two hot-swap 350W auto-ranging, redundant power supplies.
• Redundant fans - two hot-swap, dual-fan units.
• LED indicators on all critical components warn of faults,
over-temperature, and other abnormalities.
• Ten drive bays - supports slim-high or half-high Fibre Channel hot-
swap HDDs.
• Height is 3U (1U=1.75in or 44.45mm).
• Requires Netfinity Enterprise Rack or Expansion Cabinet, Netfinity
Rack, Netfinity NetBAY22 or 19in EIA-D industry standard rack.
Mounting rails are included with the controller.
• Supports long- and short-wave connections. Requires optional
GBICs for each connection. GBICs not included.
FAStT200 HA Storage Server 35422RU