Internal SCSI Cabling
The Netfinity 7600 contains a DASD backplane supporting ten hot-swap, SCA-2 compliant drive bays. The backplane is connected to the internal connector of the standard Netfinity
ServeRAID-3HB Ultra2 SCSI Adapter through a 16-bit LVD SCSI cable. External RAID support is provided through the two external 0.8-mm VHDCI connectors on the back of the
adapter. To support SCSI devices in the internal 133/89-mm (5.25/3.5-inch) half-high bays, a two-drop, 16-bit LVD SCSI cable with integrated terminator is included with the server.
This cable can be used to connect Channel B of the integrated Wide Ultra2 SCSI controller to SCSI devices in one or both of the removable media bays. Channel A, of the dual-
channel, Wide Ultra2 SCSI controller, only supports external SCSI attachment and is cabled directly to an external 0.8-mm VHDCI SCSI connector.
19K0655
9.1 GB 15K-rpm Ultra160 SCSI
Hot-Swap HDD
15,000 SL See diagram 10
19K0656
18.2 GB 15K-rpm Ultra160 SCSI
Hot-Swap HDD
15,000 SL See diagram 10
External Storage Expansion
Units
2
Form Factor
00N6xxx
7
Netfinity EXP200 Storage
Expansion Unit
3, 6
Rack (3U)
37L5857
Netfiinity EXP200 Rack-to-Tower
Conversion Kit
-
37L0xxx
8
Netfinity EXP200 350 W Redundant
Power Supply
6
-
19K11xx
9
EXP300 Storage Expansion Unit
4, 6
Rack (3U)
09N7296
EXP300 Rack-to-Tower Conversion
Kit
-
00N71xx
10
FAStT EXP500 Storage Expansion
Unit
5, 6
Rack (3U)
94G7448
Rack Power Cable Type C12
(3.7m, 12 ft.)
6
-
1. Netfinity 7600 contains an Ultra2 hot-swap backplane which limits Ultra160 HDDs to Ultra2 bus speeds.
2. Not supported by the onboard external SCSI port. Select an optional SCSI controller then refer to Appendix D: Cables-
Storage Units-Controllers to confirm the controller supports the desired External Storage Expansion Unit and to select a
supported cable. For HDD or other expansion unit options, see the specific expansion unit section.
3. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply. Optional hot-
swap Netfinity EXP200 350W Power Supply P/N 37L0xxx provides redundancy. To convert an EXP200 to a tower form
factor, Netfinity EXP200 Rack-to-Tower Conversion Kit P/N 37L5857 is required.
4. EXP300 includes a single 2 M Ultra2 SCSI cable and dual hot-swap 500 W power supplies. To convert an EXP300 to a
tower form factor, EXP300 Rack-to-Tower Conversion Kit P/N 09N7296 is required.
5. FAStT EXP500 Storage Expansion Unit includes dual hot-swap 350 W power supplies.
6. These units do not include Rack Power Cables P/N 94G7448 when shipped (for attachment to high voltage UPS or
PDU). Standard country power cords only are included. If required, order Rack Power Cables according to the number of
power supplies.
7. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish,
902=European/French, 903=European/German, 904=Danish/English, 905=Israel/English, 906=Italian/Italian, 907=South
Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication
Country Kits are included throughout.
8. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English,
079=Italy/English, 080=South Africa/English, 081=Swiss/English, 082=UK/English. Line Cords/Publication Kits are
included throughout.
9.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/
English, 58=Italian/English, 59=South Africa/English, 60=Swiss/English, 63=UK/English:- Line Cords/ Publication
Country Kits are included throughout.
10. Where ‘xx’ represents a country specific code as follows:- 36=US/English, 37=Euro/English, 41=Denmark/English,
42=Israel/English, 43=Italy/English, 44=South Africa/English, 45=Switzerland/English, 49=UK/English. Country/
Language Line Cords/Publications are included as indicated.
Diskette
Bay 1
CD-ROM
Bay 2
HH
0
4
SL
14
8
2
12
10
1
4
3
0
14
10
9
5
13
11
Removable
Media (RM)
Bays
Hot-Swap (HS)
Bays 10 x SL
-or-
7 x HH
(SCSI IDs
shown)
Netfinity NetBAY3 (NB3)
(Optional on Tower Configurations)
1. The top bay is HH; all others are configured in groups of three SL bays.
When a HH drive is installed in one of these groups, only another HH or a
single SL drive can be installed in the same group. For clarity, the SCSI IDs