Specifications
89
Updated
17/10/00
Netfinity 7100 Power, Monitors, Accessories
Part Number Description Part Number Description
Power
1,9
Conversion Kits
33L37xx
10
250 W Hot-Swap Redundant Power Supply
9
37L6860 8Ux24D Rack-to-Tower Kit
1
94G7448 Rack Power Cable Type C12 (3.7m, 12 ft.)
9
37L6859 8Ux24D Tower-to-Rack Kit
Uninterruptable Power Supply (UPS)
2
Rack and NetBAY
2,10
SUP102Y APC Smart-UPS 1000 930842P Netfinity Enterprise Rack
SUP142Y APC Smart-UPS 1400 930842X Netfinity Enterprise Expansion Cabinet
14RIxxx
12
APC Smart-UPS 1400RMB
3
9306900 Netfinity Rack
30RIxxx
12
APC Smart-UPS 3000RMB
3
9306910 Netfinity Rack (includes perforated door)
37L6862 APC Smart-UPS 5000RMB
4
9306200 Netfinity NetBAY22
Monitors
5
10L6912 Netfinity NetBAY3
3
T3347xx
11
E51 Color Monitor 15” (350-mm, 13.8” Viewable Image
Size), stealth black
6
10L6913 Netfinity Caster Set
31H2Nxx
11
E54 Color Monitor 15” (350-mm, 13.8” Viewable Image
Size), stealth black
6
37L6888
Netfinity Flat Panel Monitor Rack Mount Kit
T32N3xx
11
E74 Color Monitor 17” (403-mm, 15.9” Viewable Image
Size), stealth black
6
94G7448 Rack Power Cable Type C12 (3.7m)
10
T274Axx
11
G78 Color Monitor 17” (454-mm, 17.9” Viewable Image
Size), stealth black
6
Keyboard and Mouse
4
11AG1xx
11
T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0”
Viewable), stealth black
7
28L36xx
8
Space Saver II Keyboard
5, 7
1. Netfinity 7100 includes two 250W hot-swap redundant power supplies, with the ability to
accept up to two additional 250 W Hot-Swap Redundant Power Supplies P/N 33L37xx. To
assist in determining when an additional power supply is required to preserve redundancy, a
“Non-Redundant LED” is a standard feature of the Netfinity 7100. Predicting whether or not a
particular configuration will require an additional power supply for redundancy is very
complex. However, once the system is installed, the “Non-Redundant LED” will indicate when
an additional power supply is required. The following sample configuration is provided as a
reference.
28L36xx
9
Preferred Keyboard (stealth black)
6
28L3675 Sleek 2-Button Stealth Black Mouse
1. Includes one Netfinity NetBAY3 with casters.
2. Netfinity 7100 rack models are housed in a 19” rack mountable drawer and require one of the racks listed
here. Tower models require Netfinity 8Ux24D Tower-to-Rack Kit P/N 37L6859 for installation in a rack.
3. Netfinity 7100 tower models require Netfinity 8Ux24D Rack-to-Tower Kit P/N 37L6860 for use with a
NetBAY3. A maximum of three NetBAY3 enclosures, including the one which ships with the conversion kit,
may be stacked beneath a supported Netfinity tower server. Optional NetBAY3s must be shipped separately
and not while attached to the base configuration. See IBM Netfinity NetBAY3 Stackable Enclosure section
for supported devices.
4. Tower models includes both a mouse and keyboard. Rack models include neither.
5. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).
6. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a
keyboard tray with a flat panel display.
7. Advanced TrackPoint IV features are not available on IBM Netfinity systems.
8. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian,
50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland, 19K3832=Sweden/Finland,
19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.
9. Where ‘xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English,
31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.
10. The Netfinity 7100 ships with a standard country power cord. For connection of a Rack model to a high
voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.
2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate
3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.
5. Netfinity 7100 uses an SVGA controller (S3 Trio 3D chipset) with 4 MB of video memory.
6. Installation within a rack requires optional Monitor Compartment P/N 94G7444.
7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit P/N
37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may coexist
within the same keyboard tray.
8. The addition of a DLT tape drive may require a fourth power supply to preserve redundancy.
9. Rack Power Cable P/N 94G7448 (type C12) - one for each Power Supply, must be ordered
for power connection to a high voltage UPS or PDU.
10. Where ‘xx’ refers to a country specific code: 60=Saudi Arabia, 61=Europe, 62=Denmark,
63=Israel, 64=Italy, 65=South Africa, 66=Switzerland, 67=United Kingdom&Arabia.
11. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy,
SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.
12. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark,
ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland,
UKM=United Kingdom, EUR=Europe
Slot 1- Bus A- 66 MHz- 3.3 V or Universal
Slot 6- Bus B- 33 MHz- 5 V or Universal
Slot 2- Bus A- 66 MHz- 3.3 V or Universal
Slot 5- Bus B- 33 MHz- 5 V or Universal
Slot 4- Bus B- 33 MHz- 5 V or Universal
Slot 3- Bus B- 33 MHz- 5 V or Universal
All Slots- Full Length, 64-bit
Power Supply Quan. System Configuration Supported
Typical Non-Redundant Configuration
2 x Processors
2 3 x PCI Adapters
4 x Half-High or 5 Slim-Line HDDs
8 x 512 MB RDIMMs
Typical Redundant Configuration
4 x Processors
3
8
6 x PCI Adapters
7 x Half-High or 10 Slim-Line HDDs
16 x 512 MB RDIMMs
4
Full Configuration with Redundancy