Specifications

45
Updated
17/10/00
xSeries 330 Power, Monitors, Accessories
Part Number Description
Power
1,8
Uninterruptible Power Supply (UPS)
2
14RIxxx
10
APC Smart-UPS 1400RMB
3
30RIxxx
10
APC Smart-UPS 3000RMB
3
37L6862 APC Smart-UPS 5000RMB
4
94G7448 Rack Power Cable Type C12 (3.7m)
8
Monitors
5
06P4792 Cable Chain Technology Cable Kit
5
T3347xx
9
E51 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black
6
31H2Nxx
9
E54 Color Monitor 15” (350-mm, 13.8” Viewable Image Size), stealth black
6
T32N3xx
9
E74 Color Monitor 17” (403-mm, 15.9” Viewable Image Size), stealth black
6
T274Axx
9
G78 Color Monitor 17” (406.4mm, 16.0” Viewable Image Size), stealth black
6
11AG1xx
9
T54A TFT LCD Color Monitor (306-mm x 230-mm, 15.0” Viewable Image Size), stealth black
7
1. The xSeries 330 includes a worldwide, voltage sensing 200 W power supply and a standard country power cord.
2. For runtimes and UPS attributes see Appendix C: UPS Runtime Estimate.
3. Height is 3U. See “Rack and NetBAY” for supported IBM racks.
4. Height is 5U. See “Rack and NetBAY” for supported IBM racks.
5. The xSeries 330 uses an SVGA controller (S-3 Savage4 chipset) with 8Mb of video memory. A Cable Chain Technology Cable Kit P/N 06P4792 is required for the attachment of console
devices to one or multiple chained xSeries 330s. The kit contains a 2M (6.5 feet) KVM breakout cable for attachment to a keyboard. mouse and monitor, as well as a 2 M (6.5 feet) KVM
chaining cable for connecting two xSeries 330s together when the standard 245 mm (9.6 inches) KVM chaining cable is not long enough, A maximum of 42 xSeries 330s are supported in a
single chain. No more than one kit may be used.
6. Installation within a rack requires optional Monitor Compartment P/N94G7444.
7. Installation within a rack requires optional Netfinity Flat Panel Monitor Rack Mount Kit II P/N 37L6888 and Netfinity Rack Keyboard Tray P/N 28L4707. A space saver keyboard may
coexist within the same keyboard tray.
8. Rack Power Cable P/N 94G7448 must be ordered for power connection of a rack model to a high voltage UPS or PDU.
9. Where ‘xx’ represents a specific country code: DK=Denmark, IS=Israel, IT=Italy, SD=Saudi Arabia, SA=South Africa, CH=Switzerland, UK=UK, EU=Europe.
10. Where ‘xxx’ represents the appropriate country code as follows:- DEN=Denmark, ISR=Israel, ITA=Italy, SDI=Saudi Arabia, SAF=South Africa, SWS=Switzerland, UKM=United
Kingdom, EUR=Europe
Part Number Description
Rack and NetBAY
1,2,10
930842P Netfinity Enterprise Rack
4
930842X Netfinity Enterprise Expansion Cabinet
4
9306900 Netfinity Rack
2, 5
06P6010 Netfinity Rack Front Door Kit
3
9306910 Netfinity Rack (includes perforated front door)
5
36L9703 Netfinity Rack Extension Kit
9306200 Netfinity NetBAY22
4, 5
36L9702 NetBAY22 Rack Extension Kit
36L9701 Netfinity NetBAY3E
4, 6
37L6888 Netfinity Flat Panel Monitor Rack Mount Kit II
94G7448 Rack Power Cable Type C12 (3.7m)
10
Keyboard and Mouse
7
06P4792 Cable Chain Technology Cable Kit
7
28L36xx
11
Space Saver II Keyboard
8
28L36xx
12
Preferred Keyboard (stealth black)
9
28L3675 Sleek 2-button Stealth Black Mouse
1. xSeries 330 is housed in a 19” rack mountable drawer and requires one of the racks listed here. See IBM Netfinity Rack Cabinet and Options section for IBM rack supported devices. To
provide adequate cooling, Blank Filler Panel Kit P/N 94G6670 should be placed on the front of any unused rack space. If non-IBM racks are to be used, assure that both the front and rear
doors offer a minimum of 48% open area uniformely distributed and in line with installed servers. A clearance of 51 to 64-mm (2 to 2-1/2 inches) must be maintained between the front door
and the system unit’s front bezel. The rear door must maintain the same or greater clearance. Clearance between the EIA mounting rails and rack side covers must be less than 13-mm (1/2 -
inch) to prevent air re-circulation from back to front. Non-rack or NetBAY3E installations are not supported.
2. To enable proper cooling, optional Netfinity Rack Front Door Kit P/N 06P6010 must be installed or the front door must be removed. See also Rack P/N 9306910.
3. Provides a perforated front door replacement for the standard glass door of a Netfinity Rack P/N 9306900.
4. To enable proper cooling, the front door (bezel for NetBAY3E) must be removed.
5. Although not required, the use of an appropriate Extension Kit is recommended
6. Up to three xSeries 330s are supported for installation in a NetBAY3E. and up to three NetBAY3Es are supported while installed beneath a Netfinity 8500R. An 8500R must be installed on
top of the NetBAY3E.
7. A Cable Chain Technology Cable Kit P/N 06P4792 is required for the attachment of console devices to one or multiple chained xSeries 330s. The kit contains a 2M (6.5 feet) KVM breakout
cable for attachment to a keyboard. mouse and monitor, as well as a 2 M (6.5 feet) KVM chaining cable for connecting two xSeries 330s together when the standard 245 mm (9.6 inches) KVM
chaining cable is not long enough, A maximum of 42 xSeries 330s are supported in a single chain. No more than one kit may be used.
8. Installation within a rack requires optional keyboard tray P/N 28L4707 (stows in “ready-to-use” position).
9. Installation within a rack requires optional keyboard tray P/N 28L4707. This keyboard cannot share a keyboard tray with a flat panel display.
10. The xSeries 330 ships with a standard country power cord. For connection to a high voltage UPS or PDU, a Rack Power Cable P/N 94G7448 (type C12), must be ordered.
11. Where ‘xx’ represents country specific code: 46=Danish , 47=France, 48=Germany, 49=Italian, 50=Spanish, 51=UK English, 44=US English, and P/N 19K3831=Switzerland,
19K3832=Sweden/Finland, 19K3833=Portugal, 19K3834=Belgium, 19K3836=Russia, 19K3837=Poland.
12. Where
xx’ represents a country specific code: 25=French, 26=German, 27=Italian, 29=English, 31=Danish, 33=Norwegian, 34=Swedish/Finnish, 35=Swiss, 36=Dutch.