Specifications
22
Updated
17/10/00
To access IBM information specific to your country via the World Wide Web, use address: http://www.pc.ibm.com
xSeries 220 Internal SCSI Cabling
Non-Hot-Swap
Models
xSeries 220 non-hot-swap models are cabled internally with a five-drop, 16-bit wide LVD SCSI cable with a built-in multi-mode active terminator on one end of the cable. The other
end of the cable is attached to the internal 68-pin connector of the integrated Ultra160 SCSI controller. SCSI devices can be connected to any of the five cable connectors. If 8-bit
(narrow) devices are to be installed, a 68- to 50-pin converter (32G3925) is required for each narrow device.
Hot-Swap Models
xSeries 220 hot-swap models are cabled internally with a two-drop, 16-bit wide LVD SCSI cable. One end is connected to the internal 68-pin connector of the integrated Ultra160
SCSI controller. The first drop is designed to support a SCSI device in the 3.5-inch non-hot-swap bay, while the second drop is connected to the hot-swap SCSI backplane.The SCSI
backplane provides termination for the SCSI bus.
Other Configuration Alternatives
In the case where a RAID controller is used to support internal drives in a xSeries 220, the standard cable is moved from the onboard controller to the RAID adapter. To connect a
tape drive to the onboard or other supported SCSI controller, the two-drop cable from Media Bay Tray and LVD Cable Kit (P/N 10K2340) must be used.
External SCSI support can be obtained by installing an optional SCSI adapter or RAID controller and using appropriate external SCSI cabling.
1.Non-hot-swap HDDs are supported in bays 4...7 of non-hot swap models and in bay 4 of hot-swap models.
2.Hot-swap HDDs are supported in bays 5...7 of hot-swap models. Bay 4 supports non-hot-swap HDDs only.
3. Not supported by the onboard SCSI controller. Select an optional SCSI controller then refer to Appendix D: Cables-Storage Units-Controllers to confirm the controller supports the
desired External Storage Expansion Unit and to select a supported cable. For HDD or other expansion unit options, see the specific expansion unit section.
4. Netfinity EXP200 includes a single 2 M Ultra2 SCSI cable and a single hot-swap 350W power supply and standard country power cord. Optional hot-swap Netfinity EXP200 350W
Redundant Power Supply (P/N 37L0xxx
7
) includes an additional standard country power cord. To convert an EXP200 to match the system’s tower form factor, Netfinity EXP200 Rack-
to-Tower Conversion Kit (P/N 37L5857) is required.
5. EXP300 includes a single 2M Ultra2 SCSI cable and dual hot-swap 500 W redundant power supplies, each with its own standard country power cord. To convert an EXP300 to a tower
form factor, EXP300 Rack-to-Tower Conversion Kit (P/N 09N7296) is required.
6. Where ‘xxx’ represents a specific country code: 899=US/French, 900=European/English, 901=European/Spanish, 902=European/French, 903=European/German, 904=Danish/English,
905=Israel/English, 906=Italian/Italian, 907=South Africa/English, 908=Swiss/English, 909=Swiss/French, 910=Swiss/German, 912=UK/English:- Line Cords/ Publication Country Kits
are included throughout.
7. Where ‘xxx’ represents a country specific code:076=Euro/English , 077=Danish/English, 078=Israel/English, 079=Italy/English, 080=South Africa/English, 081=Swiss/English,
082=UK/English. Line Cords/Publication Kits are included throughout.
8.Where ‘xx’ represents a specific country code: 51=US/English, 52=European/English, 56=Danish/English, 57=Israel/English, 58=Italian/English, 59=South Africa/English, 60=Swiss/
English, 63=UK/English:- Line Cords/ Publication Country Kits are included throughout.
Bay Form
Factor
Height Front
Access
Usage
1
133 mm
(5.25”)
HH yes
IDE CD-
ROM
2
133 mm
(5.25”)
HH yes open
1
3
89 mm
(3.5”)
SL yes Diskette
4
89mm
(3.5”)
SL yes open
5...7
89mm
(3.5”)
SL
2
yes open
1. This bay does not support hard drive options. It can be used for
removable media devices such as tape drives.
2. These bays will be configured as hot-swap bays on model P/Ns
K52AXxx, K53AXxx, K54AXxx.