MSCS Four Node Cluster - Parts List
1
Note: The following sample configurations are for illustration only and may not be suitable for any specific customer installation. Customer specific MSCS
configurations require IBM approval. Contact your IBM Business Partner or IBM Marketing Representative for assistance with your specific configuration
requirements.
Part
Number
Description Qty. Usage
18RYNxx Netfinity 8500R-700 MHz/2 Mb L2, 512k Mb RAM 4 Cluster Nodes
10K2335 Netfinity 4x Accelerator Filter 4
10K2337 Netfinity Mezzanine Expansion Kit 4 Allows expansion to 8 SMP processors.
10K2166
Netfinity 8500R 700 MHz/ 2 Mb Upgrade with Pentium III Xeon
Processor
28 7 per node, total of 8 SMP processors per node
37L7206 36.4 GB 10K-4 Ultra160 SCSI Hot-Swap SL HDD 8 2 per node, mirrored NOS, attached to ServeRAID
36L6086 IBM Netfinity ServeRAID-3HB Ultra2 SCSI Adapter 4 1 per node for NOS HDDs. Install in PCI slot 1
34L1501 Netfinity 10/100 Ethernet PCI Adapter 2 8 Public LAN - slot 6/ interconnect slot 7
00N6881 Netfinity FAStT Host Adapter 8 2 per node, each attaches to one of the two Fibre Hubs. Install in PCI slots 3 and 4.
37L0xxx Netfinity EXP200 350 W Redundant Power Supply II 4 1 per node, provides power supply redundancy for each node
20L0247 256 MB ECC SDRAM RDIMM II Memory 8 2 per node to increase memory to 1GB
28L4454 Netfinity Memory Expansion Card 4 1 per node, to expand for additional memory
02K65xx UltraSlim 56 W AC Adapter 4 Provides an independent backup power source for systems management
Storage Subsystems
2109S08 SAN Fibre Channel 8 Port Switch 2
Redundant short-wave (SW) connections from each of four nodes to Netfinity Fibre
Channel RAID Controller Unit. Each switch includes four standard SW BBICs
09L5403 Additional Power Supply 2 Hot-Swap redundant power supply for SAN Fibre Channel Switch
03K9308 Netfinity Fibre Channel Short-Wave GBIC 10 8 for adapters and 2 for switches
SFCU1xx Netfinity Fibre Channel RAID Controller Unit 1 Attaches to 6 EXP200s, with Failsafe Controller - two attachments to the hubs
01K7296 Netfinity Fibre Channel Failsafe RAID Controller 1 Installs in Controller Unit, providesredundant path to EXP200s
00N6xxx Netfinity EXP200 Storage Expansion Unit 6 One LVDS attachment to RAID Controller Unit per EXP200, max, of 60 HDDs
37L7206 Netfinity EXP 36,4 GB 10K-4 Ultra160 SCSI Hot-Swap HDD 58 A minimum of four RAID 5 HDDs( 3 plus a hot-spare) with a maximum of 58
37L7204 Netfinity EXP 9.1 GB 10K-4 Ultra160 SCSI Hot-Swap HDD 2 Mirrored Quorum HDDs
00N79xx DLT Tape Library 1 Tape subsystems are optional. The 3502R14 includes a 3 M cable and PCI controller
37L6862 APC Smart-UPS 5000RMB
2
4 Power connections are intra-rack only
2
Storage Cables
03K9306 Netfinity Fibre Channel 5 M Cable 10 2 x 4 nodes to hub, 2 hub to RAID controllers
03K9310 Netfinity 2 M Ultra2 SCSI Cable 3 RAID controller to EXP200s
03K9311 Netfinity 4.2 M Ultra2 SCSI Cable 3 RAID controller to EXP200s
Internet Components
-CISCO Ethernet Switch
4
1 Standard configuration supports interconnection up to 4 nodes
- Standard CAT5 Cables
4
8 2 per node for cluster interconnect/network access
Other Non-Rack
Customer
Supplied
Ethernet System Management Cables 8 Provides interconnection between Advanced System Management Adapters.
28L36xx Space Saver II Keyboard (1U) 1 Includes TrackPoint
11AG1xx Flat Panel Monitor 1
37L6888 Flat Panel Monitor Adapter 1