Service manual
71
6 Replacing Parts
Safety Information
Follow the procedures listed below to ensure safe handling of components and to prevent harm to both you
and the server:
• Use an anti-static wrist strap and a grounding mat, such as those included in the Electrically
Conductive Field Service Grounding Kit (HP 9300-1155).
• Handle accessory boards and components by the edges only. Do not touch any metal-edge
connectors or any electrical components on accessory boards.
• Do not wear clothing subject to static charge build-up, such as wool or synthetic materials.
WARNING Hazardous voltages are present inside the server. ALWAYS remove AC power from
the System Processing Unit and other associated assemblies while working inside
the unit. Serious injury may result if this warning is not observed.
Service Tools Required
Service of this product may require one or more of the following tools:
• Electrically Conductive Field Service Kit (P/N 9300-1155)
• CE Peripheral Exerciser Disk Kit (45935-63210)
• Datacomm Test Hood, 9-pin (24540-60010)
• Datacomm Test Hood, 25-pin parallel (24540-60011)
• 1/4 inch Flat Blade Screwdriver
• ACX-15 Torx
®
Screwdriver
Replacing the Bezel
To remove and replace the front bezel on both models of the HP NetServer, LH 3000r and LH 3000 perform
the following procedures.
LH 3000
LH 3000r
HP NetServer's Front Bezel