Service manual

Chapter 2 System Information
20
Altitude
Operating
-30 to 3,045 m (~ 10,000 ft)
Non-operating
-30 to 12,180 m (~ 40,000 ft)
Acoustic Emissions
Sound level (LpA): 58<dBA
Physical Requirements
Minimum Clearance
HP NetServer LH 3000r HP NetServer LH 3000
Front
1 m (39 inches) 1 m (39 inches)
Sides
2.5 cm (1 inch) 2.5 cm (1 inch)
Top
2.5 cm (1 inch) 2.5 cm (1 inch)
Back
15 cm (6 inches) 15 cm (6 inches)
Weight and Dimensions
NOTE Use one person for every 40 pounds of NetServer weight when lifting it.
LH 3000r LH 3000
Height
354.7 mm (14 in) 494.8 mm (19.5 in)
Width
482.6 mm (19 in) 350.5 mm (13.8 in)
Depth
749.2 mm (29.5 in) 724.2 mm (28.5 in)
Weight Empty
35 - 50 kg (77 - 110 lbs.) 35 - 50 kg (77 - 110 lbs.)
Power Requirements
Power supply type Auto-Ranging
Input voltages:
Nominal:
Range:
100 to 127 VAC ~ 8.3 A at 50Hz
200 to 240 VAC ~ 3.9 A at 60 Hz
90 to 132 VAC at 47 - 63 Hz
180 to 264 VAC at 47 - 63 Hz
Power availability: 550 W continuous