Service manual

Chapter 2 System Information
19
Primary
Processor
Primary
VRM
Configuratio
n
Switches
Secondary
RM
Secondary
Processor
System Board
CAUTION Do not remove the processor from its bag until you are ready to install it. Make sure
the bag remains sealed. Before you remove a processor from the anti-static
container, touch a grounded, unpainted metal surface on the HP NetServer to
discharge static electricity.
Do not change the processor speed switches as this can result in unreliable or
intermittent performance, and data integrity may also be at risk.
l Use only processor upgrade kits with the same HP product number. This ensures the processor
type, clock speed, and cache size match, and processor stepping are compatible.
l Be sure that the VRM and the processor module associated with it are both in either the primary
or the secondary pair of slots.
Technical Specifications
The specifications listed below vary if a mass storage device is installed that has more stringent
environmental limits. Make sure that the operating environment for the server is suitable for all the mass
storage devices being used.
Thermal
Operating
5° to 35° C (41° to 95° F)
Non-operating
-40° to +65° C (-40° to +149° F)
Humidity
Operating
20% to 80% relative humidity, non-condensing
Non-operating
5% to 95% relative humidity, non-condensing