- Hewlett-Packard User Guide Printer LCS60
Table Of Contents
- TR.PDF
- 1.PDF
- 2.PDF
- Hardware Installation
- Introduction
- Site Preparation
- Assembly
- Installing the LCS60
- Rack Mounting
- Wall Mounting
- Table-Top Mounting
- Connecting the System Console
- Direct Connection to the LCS60
- Connection through a Data Switch
- Connection through Modems
- Connection through StarKeeper II NMS
- Connecting the Fiber Interface
- Configuration of the Lucent Technologies Data Switch ± LCS60
- Power and Grounding
- Verify LCS60 Console Connection
- Verify Fiber Connection
- Configure the LCS60
- LAN Connections
- Hardware Installation
- 3.PDF
- 4.PDF
- 5.PDF
- 6.PDF
- 7.PDF
- 8.PDF
- Administration
- Basics
- Logging On
- lcsadm Interface
- Typical Administrative Tasks
- Backup and Restore Operations
- Network Access Password Option
- Status
- Error Messages
- Administration
- 9.PDF
- 10.PDF
- 11.PDF
- 12.PDF
- 13.PDF
- 14.PDF
- 15.PDF
- 16.PDF
- IX.PDF

Error Messages
Incoming Error Messages
ipaserrno=<error number>
An internal error occurred with the IP Address Server software logic.
slip is temporarily disabled
Either insufficient resources are available to allocate another SLIP session
or one of the required system processes cannot be contacted to set up the
user’s session. Try again later; if the problem persists contact the LCS60
administrator.
may have only one -s option, got <dkserver name> and <name from
user>
The IP/SLIP client attempted to bypass NAC security by entering a -s
<name from user> option on his/her data switch dialstring even though
he/she had been authorized to call <dkserver name>. The call is refused
and a message logged in the /usr/adm/lcs/slip.log file.
missing -s %h option in dksrvtab(4) ’slip’ file
The slip file in directory /etc/opt/dk/srvtab does not have the mandatory
-s%h option on the sliptoss command line. This error message suggests
that this file was not correctly installed or was edited incorrectly when
adding originating group security patterns.
ip address <IP address> is invalid
The IP/SLIP client entered a syntactically invalid IP address on his/her
data switch dialstring. The IP address should be in dotted notation, i.e.,
WWW.XXX.YYY.ZZZ, where WWW, XXX, YYY, and ZZZ are decimal
numbers between 1 and 254 and must conform to the Internet network
numbering conventions.
priq=<priority queue level>, must be 0 or 1
The IP/SLIP client gave an invalid value for the <priority queue level> on
the data switch dialstring.
vjslots=<# of vjslots>, must satisfy 3 <= vjslots <= 64
The IP/SLIP client specified an out of bounds number on the data switch
dialstring for the number of Van Jacobsen compression slots.
Issue 3 C-11










