Specifications
7
Store in Addition Description
Chromatograms Stores all available chromatograms (from each detector and/or signal)
Spectra for quantified Stores spectra from all peaks that have been identified and quanti
peaks fied as compounds in the calibration table.
Raw data Stores the acquired data in addition to the calculated result.
Note:
This setting has a significant effect on the amount of storage space
required for each run in the ChemStore C/S database. For example
ChemStation data which is created from 3D techniques such as a
liquid chromatography diode array detector will require more
storage space than a 2D technique such as gas chromatography.
Sequence Stores the ChemStation sequence.
Method Stores the ChemStation method
Table 4
Store in Addition study settings
Note: The custom database con-
figuration must be planned as a
project with Agilent database con-
sulting specialists prior to system
installation. The size of the
Agilent ChemStore C/S database
is based on an Agilent ChemStore
C/S system which has an average
distribution of all Agilent
ChemStation 2D and 3D tech-
niques. Also, all Store in Addition
checkboxes are
enabled for all studies, as shown
in figure 1. The space require-
ments for runs stored in the
Agilent ChemStore C/S database
will vary depending on your envi-
ronment. A run is defined as a sin-
gle set of results produced from a
single sample acquisition or
reprocessed by an Agilent
ChemStation which has been
transferred and stored in the
Agilent ChemStore C/S database.
The actual amount of space con-
sumed by each run in an Agilent
ChemStore C/S database will vary
depending on:
• the Store in Addition
to Result settings of the study
to which the run is assigned
(table 4), and
• the technique and complexity
(numbers of peaks, Agilent
ChemStation reports, custom
fields, and so on) of your chro-
matography for that run.
• For details on the size of
raw data files by technique,
please refer to table 5.
Supported Agilent Chem-
Station software
Agilent ChemStore C/S can be
used with the following Agilent
ChemStation software:
• Agilent ChemStation for gas
chromatography, revision
A.09.03 or later,
• Retention time locking
software, add-on module for
Agilent ChemStation for gas
chromatography,
• Agilent ChemStation for liquid
chromatography, revision
A.09.03. or later,
• Gel permeation chromatogra-
phy software add-on module
for the Agilent ChemStation for
LC,
• Agilent ChemStation for
capillary electrophoresis, revi-
sion A.09.03. or later,
• Agilent ChemStation for liquid
chromatography mass selective
detection, revision A.09.03 or
later.
• Agilent ChemStation for analog
signal acquisition, revision
A.09.03. or later,
• Agilent ChemStation for
capillary electrophoresis mass
selective detection, revision
A.09.03. or later,
• Agilent ChemAccess C/S
remote instrument control, and
• Agilent ChemStation Plus
Method Validation Pack A.01.02.
Technique Average file size (kB)
GC/LC 2D – 50
LC 3D – 60
LC/MS 3D – 750
CE 3D – 600
Table 5
Average raw data file size by technique