Specifications
Working with Agilent ChemAccess C/S
view of the Agilent ChemStation.
If the same results are retrans-
ferred to the server, Agilent
ChemAccess C/S employs data
versioning to ensure that an entire
record of the analysis is recorded.
18
Data storage and organization
Agilent ChemAccess C/S enables
the Agilent ChemStation results
(raw data, methods and
sequences) to be securely stored
on the Agilent ChemAccess
Windows NT server. The results
can be transferred automatically
at the end of each run or interac-
tively through the data analysis
Client hardware requirements
Agilent ChemStation and
ChemAccess C/S
The PC client should conform to
the requirements as specified in
Agilent ChemStation
Specifications (Agilent publica-
tion number 5988-5314EN). In
addition to these requirements
further 8 MB memory is required
for network connectivity software
and Agilent ChemAccess C/S soft-
ware.
Agilent ChemStation,
ChemAccess and ChemStore
C/S
Configure the client using the
Agilent ChemStore C/S client
hardware requirements specified
in this document.
Client software requirements
The ChemAccess C/S client mod-
ule can be added to the Agilent
ChemStation. The ChemAccess
C/S module is supported with the
following ChemStation software
packages:
• Agilent ChemStaion for gas
chromatograhpy mass selective
detection revision C.00.xx,
• Agilent ChemStation for gas
chromatography, revision
A.08.04. or later,
• Retention time locking
software, add-on module for
Agilent ChemStation for gas
chromatography,
• Agilent ChemStation for liquid
chromatography, revision
A.08.04. or later,
• Gel permeation chromatography
software add-on module for the
Agilent ChemStation for LC
• Agilent ChemStation for
capillary electrophoresis,
revision A.08.04. or later,
• Agilent ChemStation for liquid
chromatography mass selective
detection, revision A.08.04.or
later,
• Agilent ChemStation for analog
signal acquisition, revision
A.08.04. or later, and
• Agilent ChemStation for capil
lary electrophoresis mass selec
tive detection, revision A.08.04.
or later.
Each Agilent ChemStation that is
integrated in an Agilent Chem-
Access C/S system should con-
form to the following Agilent
ChemStation and Windows soft-
ware revisions:
• ChemStation for GC, LC,
LC/MSD, CE and A/D revision
A.08.04 or higher on Windows
NT 4.0 Service Pack 6a or
Windows 2000 Service Pack 2
• GC/MSD ChemStation revision
C.00.xx on Windows NT 4.0
Service Pack 6a.
• GC/MSD ChemStation revision
D.00.xx on Windows NT 4.0
Service Pack 6a or Windows
2000 Service Pack 2.
Note:
Agilent ChemAccess C/S currently
does not support the Agilent
ChemStation for UV-visible
systems.
Agilent ChemAccess C/S — System Requirements