- HP Printer User Manual
Table Of Contents
- hpLaserJet 9055mfp (Q3631A) hpLaserJet 9065mfp (Q3632A)
- service manual
- Contents
- How to use this manual
- Safety
- MFP overview
- Overview of system
- hpLaserJet9055mfp/9065mfp product specifications
- Central cross-sectional view
- Drive system diagram
- Fuser/web drive section
- Drum drive section
- Developing drive section
- Paper feed/vertical conveyance/tray up drive sections
- Tray1 paper feed/automatic duplex unit (ADU) pre-registration drive section
- Charging and transfer/separation wire cleaning drive section
- Automatic Duplex Unit (ADU) conveyance drive section
- Paper exit drive section
- Toner supply drive section
- Optics drive section
- MFP unit explanation
- MFP disassembly/assembly
- External section
- Drive section
- Scanner section
- Laser scanner unit
- Drum unit
- Corona unit
- Screws that must not be removed
- Removing and reinstalling the charging corona unit
- Removing and reinstalling the charge control plate
- Replacing the charging wires
- Removing and reinstalling the charging wire cleaning unit
- Removing and reinstalling the PCL
- Cleaning the charging corona unit/PCL
- Removing and reinstalling the transfer/separation corona unit
- Removing and reinstalling the plunger prevention plate
- Replacing the transfer/separation wires and transfer/separation wire cleaning block
- Removing and reinstalling the TSL unit
- Developing unit
- Toner supply unit
- Cleaning/toner recycle unit
- Paper feed units of Trays2 and3
- Removing and reinstalling the paper feed unit
- Removing and reinstalling the paper feed Trays2 and3
- Removing and reinstalling the paper pick roller and pick roller rubber
- Removing and reinstalling the separation roller rubber
- Replacing the pre-registration and feed clutches (MCs)
- Replacing the wires
- Wire lengths
- Installing wires
- Paper feed unit of Tray3
- Removing and reinstalling the paper feed unit
- Removing and reinstalling paper feed Tray 3
- Removing and reinstalling the paper pick roller and pick roller rubber
- Removing and reinstalling the separation roller rubber
- Replacing the pre-registration and feed clutches (MCs)
- Replacing the wires
- Wire lengths
- Installing wires
- Tray1
- Vertical conveyance section
- ADF unit
- Pulling out and reinstalling the ADU stand
- Cleaning the paper mis-centering PS (PS70)/leading edge PS (PS43)
- Removing and reinstalling the registration MC (MC1)
- Removing and reinstalling the second paper feed unit (registration assembly)
- Cleaning the registration PS (PS44)
- Removing and reinstalling the registration roller
- Removing and reinstalling the pre-transfer roller
- Cleaning the automatic document feeder paper reverse PS (PS45)/ Reverse/Exit PS (PS46)
- Removing and reinstalling the ADF reverse roller
- Removing and reinstalling the ADU stand
- Removing and reinstalling the pre-registration roller
- Removing and reinstalling the ADU conveyance roller3 and4
- Removing and reinstalling the ADU conveyance roller1 and2
- Removing and reinstalling the paper reverse/exit roller
- Fuser
- Removing and reinstalling the fuser
- Removing and reinstalling the fuser (top)
- Removing and reinstalling the web cover
- Removing and reinstalling the cleaning web
- Replacing the fusing heater lamps (L2, L3)
- Replacing the fusing heater lamp (L4)
- Removing and reinstalling the fusing separation claw (upper) unit and fusing separation claws (up...
- Removing and reinstalling the fusing separation claw (lower) unit and fusing separation claws (lo...
- Removing and reinstalling the fusing upper roller
- Removing and reinstalling the fusing lower roller
- Removing and reinstalling the decurler roller
- Removing and reinstalling the fusing temperature sensors1 and2
- Removing and reinstalling the thermostat/U (TS1)
- Removing and reinstalling the thermostat/L (TS2)
- Product comparison
- Environmental Product Stewardship Program
- Terminology cross-reference
- Index
- automatic document feeder (Q3644A)
- 4000-sheet high capacity input (A4/Letter - Q3637A) (A3/Ledger - Q3638A)
- Contents
- HCI overview
- HCI unit explanation
- HCI disassembly/assembly
- Explanation
- Paper feed section
- Cleaning the paper dust removing brush
- Cleaning the HCI feed PS (PS106)/HCI first paper feed PS (PS107)
- Removing and reinstalling the pick roller unit
- Replacing the pick roller rubber/feed roller rubber
- Replacing the separation roller rubber
- Replacing the HCI feed MC (MC101)/HCI first paper feed MC (MC102)
- Replacing the Q3637A up/down wires
- Replacing the Q3638A up/down wires
- Index
- stapler/stacker (Q3633A) multifunction finisher (Q3634A)
- Contents
- Finisher overview
- Finisher unit explanation
- Finisher disassembly/assembly
- External section
- Removing and reinstalling the booklet tray (Q3634A only)
- Removing and reinstalling the top cover/1
- Removing and reinstalling the top cover/2
- Removing and reinstalling the side cover
- Removing and reinstalling the front door
- Removing and reinstalling the rear cover
- Removing and reinstalling the main tray
- Removing and reinstalling the main paper exit opening cover
- Removing and reinstalling the booklet paper exit opening cover (Q3634A only)
- Conveyance section
- Main tray section
- Stacker section
- Stapler section
- External section
- Index
- post insertion kit (Q3636A)
- punch kit (Q3689A, Q3635A, Q3690A, Q3691A)

ENWW Safety warnings 15
Safety
Measures to take in case of an accident
If an accident has occurred, the distributor who has been notified first must immediately take
emergency measures to provide relief to affected persons and to prevent further damage.
If a report of a serious accident has been received from a customer, an on-site evaluation must
be carried out quickly and HP must be notified.
To determine the cause of the accident, conditions and materials must be recorded through
direct on-site checks, in accordance with instructions issued by HP.
Conclusion
Safety of users and customer engineers depends highly on accurate maintenance and
administration. Therefore, safety can be maintained by the appropriate daily service work
conducted by the customer engineer.
When performing service, each MFP on the site must be tested for safety. The customer
engineer must verify the safety of parts and ensure appropriate management of the equipment.
● When using any solvent, ventilate the room well.
Breathing large quantities of organic solvents can
lead to discomfort.
● Toner and developer are not harmful substances,
but care must be taken not to breathe excessive
amounts or let the substances come into contact
with eyes, and so forth. It may be stimulative.
If the substances get in the eye, rinse with plenty of
water immediately. When symptoms are noticeable,
consult a physician.
● Never throw the used toner bottle and toner into fire.
You may be burned due to dust explosion.
WARNING: Handling of service materials










