User Manual

Table 26 Application modules—Error log messages (continued)
DescriptionNo.Log messageID
Failed to allocate LUN object: out
of resources.
811QLBI_GetLunList: LUN allocation failed for LunId %d41771
Failed to allocate LUN object: out
of resources.
1034QLFC_Login: VpIndex (%d) out of range41994
Login attempted using Fibre
Channel VP index that has not
1035QLFC_Login: VP Index 0x%x not configured41995
been configured. Operation
attempted on an unconfigured VP.
Attempting login but Fibre Channel
connection cannot be opened.
1042QLFC_Login: Can't open connection42002
Attempting logout of device for
which there is no active path
(WWPN not found).
1064QLFC_Logout: No active path to device. WWPN:
%.2X%.2X%.2X%.2X%.2X%.2X%.2X%.2X
42024
Logout attempted using Fibre
Channel VP index which has not
1067QLFC_Logout: VP Index 0x%x not configured42027
been configured. Operation
attempted on an unconfigured VP.
Event notification: Fibre Channel
processor encountered a system
1108QLFC_HandleTeb: System Error42068
error (unrecoverable firmware
error).
Event notification: Fibre Channel
driver encountered a fatal error.
1109QLFC_HandleTeb: Driver Fatal Error42069
Event notification: Fibre Channel
port logged out.
1112QLFC_HandleTeb: FC Logout.42072
Failed to allocate object for iSCSI
session: out of session resources.
1282QLIS_AllocateSessionObject: Out of session resources.42242
Received an iSCSI PDU with a
duplicate CmdSN. Command PDU
will be dropped.
1292QLIS_EnqueueiScsiPdu: Duplicate PDU, CmdSN %d (0x%x),
dropping it.
42252
Unable to allocate iSCSI initiator
object while initiating a session.
1298QLIS_InstantiateSession: Can't add Initiator to the database42258
Exceeded the number of iSCSI
hosts allowed to connect to
mpx100
1299#%d: QLIS_InstantiateSession: Maximum number (%d) of
allowed hosts already logged in
42259
Failed to execute iSCSI command
PDU due to its CmdSN being out
1444QLIS_ProcessStartTrb: [%d] CmdSN %ld is out of range
(%ld—%ld), Cdb[0] 0x%02X, DataXferLen 0x%x.
42404
of range. Log message provides
the incorrect CmdSN, the valid
CmdSN range, the first byte of the
CDB, and the length of the data.
Event notification: iSCSI driver
encountered a fatal error.
1688QLIS_HandleTeb: Driver Fatal Error42648
Event notification: an IOCTL
request was received to unload the
iSCSI driver.
1689QLIS_HandleTeb: Unload Driver.42649
Event notification: attempt to
connect to the iSNS server failed.
1694QLIS_HandleTeb: iSNS Connection Failed42654
iSNS connection failed2052QLSC_CollectBUVUIO: Allocation of DSD failed43012
122 Log data