Owner's manual
Installation
HP AutoSYNC User’s Guide—522580-017
2-9
Install the AutoSYNC EMS templates
down AutoSYNC, as recommended below in Shutting Down AutoSYNC, you will need
to add a step to activate the syncusers using the ACTIVATE SYNCUSER command.
Update the shutdown procedures to include the shut down steps described below in
Shutting Down AutoSYNC.
Install the AutoSYNC EMS templates
The AutoSYNC EMS templates are in the file ZASYTMPL. Please refer to the HP EMS
template installation instructions to perform this step.
Shutting Down AutoSYNC
For an orderly shutdown of AutoSYNC, the following steps are recommended:
1. Use the SUSPEND SYNCUSER command to suspend all AutoSYNC users.
2. Wait for active synchronizations to complete. Use the STATUS SYNC command to
display the active synchronizations.
3. Stop the AutoSYNC monitor process with the AUTOSYNC command STOP
MONITOR.
Note that there are no ill effects resulting from stopping the monitor without first
suspending the syncusers. AutoSYNC still makes sure that each active
synchronization has completed before shutting down. Suspending the syncusers
simply provides better control of synchronization activity when the monitor is eventually
restarted.
Installing a New Version of AutoSYNC
Updating AutoSYNC requires the following steps:
1. Use the SUSPEND SYNCUSER command to suspend all AutoSYNC users.
2. Wait for active synchronizations to complete. Use the STATUS SYNC
command to display the active synchronizations.
3. Stop the AutoSYNC monitor process.
The monitor process is stopped using the AUTOSYNC command STOP
MONITOR.
4. Replace the product files on disk.
See section Install the AutoSYNC Product Files
above.
5. If required, install the EMS templates. See section Install the AutoSYNC EMS
templates above.
6. Start the monitor process. See section Start the Monitor Process
above.