Manual

Chapter Seven – Specifications
Tandem 5142-xSE Rackmount Tape Subsystems User Guide 35
7.1 Electrical
7.1.1 Input Power
-48 Volts DC
7.1.2 Internal DC Power:
+5, +12 volts
7.2 Physical
7.2.1 Dimensions
L113" x W19" x H7.0"
7.2.2 Shipping weight
27 lbs.
7.2.3 Interfaces
SCSI-2, differential
Connectors 50-pin Centronics
7.2.4 Environmental Specifications
Operating Temperature:
5ºC to 40ºC with tape loaded
Nonoperating Temperature:
-40ºC to 45ºC with media installed
-40ºC to 70ºC without media installed
Operating Humidity:
20% to 80% relative humidity with tape loaded
Nonoperating Humidity:
5% to 95% relative humidity
Heat dissipation:
90W (342 BTU/hr) maximum