Manual
Chapter Five - SCSI Bridge Electronics
Tandem 5142-xSE Rackmount Tape Subsystems User Guide 23
5.10.2 Changing a Setting
Depending on the menu item, alter settings by the appropriate method explained below. When
the instruction reads PRESS to Alter you have the option of exiting from the editing
mode ore remaining in the editing mode to review the settings.
Numeric-Entry Method
With this method you change settings by entering a decimal or hexadecimal number, digit-by-
digit. The LCD shows the instruction PRESS to Incremnt while a highlight indicates
what digit is alterable. You increment the digit by pressing the mode switch. If there is no switch
activity for four seconds, the highlight proceeds to the right to the next digit. When the highlight
proceeds past the rightmost digit, the display shows PRESS if Done, allowing you to confirm
the changes. If the numerical value requires additional editing, do not press the mode switch. Wait
until the highlight restarts at the leftmost digit and then continue editing the setting.
SCSI ID:
[00]
PRESS to
Alter
SCSI ID:
[01]
PRESS if
Done
SCSI ID:
[01]
PRESS to
Incremnt
Figure 27 Numeric entry example
Pick-Entry Method
This method of configuration allows you to select from a predefined list of items. When PRESS
to Scroll displays on the LCD, you can view the list of items by repetitively depressing the
mode switch. When the switch is inactive for four seconds, the instruction PRESS if Done
appears to allow you to confirm the setting. If you do not want the setting wait until the PRESS
to Scroll instruction appears on the LCD, and then continue editing.
BaudRate
9600
bps
PRESS to
Scroll
BaudRate
1200
bp
s
PRESS to
Scroll
BaudRate
9600
bps
PRESS to
Alter
BaudRate
19K2
bps
PRESS if
Done
BaudRate
2400
bps
PRESS to
Scroll
Figure 28 Pick entry example