Instruction Manual
Troubleshooting
M8701A / M8702A ACL Tape Library Installation and User’s Guide—694636-001
5-20
Main Error Code Descriptions
DC I2C Bus failure
!
Power-cycle the device.
!
Power down the Library and
reseat the library controller
from the back panel.
DD Warning event. See DD in “Warning
events”
DE Warning event. See DE in “Warning
events”
E2 Unsupported hardware detected.
Some hardware that is connected to
the requires updated firmware.
Update the firmware to the current
version.
F0 Drive exceeded temperature
specification
!
Check ambient temperature to
ensure that it is within
operating specifications.
!
Check all fans to determine
whether they are working
properly.
F1 Library controller lost communication
with the drive
!
Power-cycle the device and
retry the operation.
!
Re-seat the tape drive to
ensure a good connection to
the device.
F2 Drive sled not present
!
Power-cycle the device and
retry the operation.
!
Re-seat the tape drive to
ensure a good connection to
the device.
F3 Drive hardware error
!
Cycle power, after several
occurrences,
!
Contact technical support
F4 Time allotted for drive loading
exceeded
!
Check that the tape cartridge
is supported and has not
exceeded its usage life.
Inspect it for damage.
!
Retry the operation.
!
Clean the drive. The error sub-
code 00 indicates drive 1, sub-
code 01 indicates drive 2, and
so on.
Table 5-2. Main Error Codes
Error Code Description Details and Solution