Instruction Manual
Troubleshooting
M8701A / M8702A ACL Tape Library Installation and User’s Guide—694636-001
5-27
Warning Events
63 Invalid cartridge. Drive has
rejected the cartridge as
invalid.
!
Check the cartridge for damage. It could
be a defective cartridge.
!
Make sure that the cartridge is
compatible with the drive.
!
Verify that the cartridge is not a firmware
upgrade tape. Initiate the firmware
upgrade process before loading a
firmware upgrade tape into the drive.
64 Invalid cleaning cartridge.
Drive has rejected the
cartridge as invalid.
!
Verify that the cartridge is a cleaning
cartridge.
!
Check the cartridge for damage. It could
be a defective cartridge.
!
Make sure that the cartridge is
compatible with the drive.
!
Verify that the cartridge is not a firmware
upgrade tape. Initiate the firmware
upgrade process before loading a
firmware upgrade tape into the drive.
65 Invalid upgrade cartridge.
Drive has rejected the
cartridge as invalid.
!
Verify that the cartridge is a firmware
upgrade cartridge, not a data or cleaning
cartridge.
!
Check the cartridge for damage. It could
be a defective cartridge.
!
Make sure that the cartridge is
compatible with the drive.
80 Movement retry. Robotics
movement did not succeed
but was successful on a
retry.
If this event becomes excessive, contact
customer support.
81 Drive sled fan alert. Fan
motion has stopped.
!
Check the tape drive fan on the Library
back panel to see whether the fan is
operational and not obstructed.
!
If this event continues, contact customer
support.
82 Clean request from the
tape drive
Clean the indicated tape drive.
Table 5-6. Warning Event Codes
Event Code Description Details and Solution