User guide

Error Recovery Procedures and Fault Symptom
Codes
N1525A ACL Installation and User’s Guide527339-003
C-6
Control Error Codes
2013 Ctl. Firmware Error A, B, 1
2014 Ctl. Firmware Error A, B, 1
2015 Ctl. Firmware Error A, B, 1
2016 Ctl. Firmware Error A, B, 1
2030 LTO Timeout Error During powerup, communication with one of the
LTO drives was unsuccessful.
A, B, 3, 1
2031 LTO Timeout Error While trying to update the front panel,
communication with one of the LTO drives was
unsuccessful.
A, B, 3, 1
2032 LTO Timeout Error Communication with LTO drive 1 was
unsuccessful (sequential mode)
A, B, 3, 1
2033 LTO Timeout Error Communication with LTO drive 2 was
unsuccessful (sequential mode)
A, B, 3, 1
2034 LTO Timeout Error While attempting to update the cartridge map,
communication with one of the LTO drives was
unsuccessful.
A, B, 3, 1
204x Invalid Ctl Msg An illegal message type code was received. This
can be the result of receiving a NULL type code, a
status code without a command being active, or a
command code while a command is currently
active.
A, B, 1
205x No Free Queues The system could not allocate a free queue A, B, 1
206x Calib. Error Port x When trying to locate the unit attached to port x,
the pass-thru elevator reached the top of rail.
A, B, 4, 1
206f Pass-thru Init Error The pass-thru elevator did not travel a minimum
distance to reach the top of its travel.
A, B, 4, 1
2070 Command Timeout Enter to reboot. The ten minute timer was
exceeded when trying to fetch from a drive.
A, 3, 2, 1
2071 Command Timeout Internal error only. Not reported to the operator or
host.
D, 1
2072 Command Timeout Power Down, Wait 30 seconds, Power Up.
Occurs if the power is cycled too quickly and the
LTO drive comes up in an error state and doesn't
communicate with the library controller. Also
occurs if a drive is removed from a dual drive
library and the unit is not re-configured (using the
ESC button).
B, 3, 1
FSC Message Description ERP