System Fault Codes (0xxx)
System Fault Codes (0xxx)
FSC Message Description ERP
0101 Unused Interrupt An undefined interrupt occurred A, B, 1
0102 Enqueue'g a Null Ptr A NULL pointer was passed to one of the
enqueing functions. This is generally a firmware
bug.
A, B, 1
0103 Invalid Cmd Rec'd An illegal trace command was received by the
trace process.
A, B, 1
0201 Trc. Comm Open Error The trace port could not be opened. A, B, 1
0301 Novram Init. Error A failure occurred when trying to initialize the
Novram.
A, B, 1
0302 Novram Chksum Error A checksum error was detected while reading the
Novram.
C, 1
0303 Novram Program Error A problem was detected while trying to update the
Novram.
A, B, 1
0304 Novram Downld. Error An error was detected while trying to download
configuration data.
D, 1
0305 Novram Data Error An error was detected while trying to validate the
Novram.
D, 1
0306 Novram Update Error A problem was detected while trying to update the
Novram.
A, B, 1
0401 Invalid Display Char Indicates a problem in the LCD display routines. D, 1
0402 Invalid Display Line Indicates a problem in the LCD display routines. D, 1
0501 Barcode Comm. Error The barcode comm port could not be opened. A, B, 1, 13
0601 Clock Init. Error The real-time clock could not be initialized. A, B, 1
0602 LP-RAM Init. Error An error occurred in the low-power ram
initialization.
A, B, 1
0603 Clock Download Error An error occurred while downloading real-time
clock information.
D, 1
0701 Slv. Comm Open Error Failed to open a Slave comm port. A, B, 1, 3
0801 Not In Br. Menu Mode The device is not in browser menu mode D, 1
0802 Invalid Novram Upd. An invalid novram update occurred in browser
mode
D, 1
0803 Executing Immed. Cmd Executing an Immediate command in browser
mode