Specifications
For installing the BBWC battery onto the bracket, the mounting bracket has:
• A C-hook to restrain the battery cable
• Two battery restraining clips to restrain the BBWC battery
431
Mezzanine foot C-hookBattery restraining clips
2
Mezzanine post loop
Installing the Controller Board
Mezzanine slot support and preference:
The HP Smart Array P700m/512 Controller is only supported in slots 1 or 3 in Integrity i2 server
blades, it is not supported in mezzanine slot 2. If you need to remove the cache module to transfer
data, the BBWC battery must remain connected so that the data is preserved. HP recommends
installation into mezzanine slot 3, with a mezzanine blank or mezzanine card in slot 1 so the
cache module and battery can be removed together.
If you are unable to use mezzanine slot 3, you will have to remove the mezzanine card in slot 2,
BBWC battery, and battery mounting bracket to gain access to the cache module.
Use the procedure for installing standard mezzanine cards to install the SAS controller board,
see “Installing mezzanine cards” (page 36) for more information.
Upgrading or replacing controller options
Replacing the 512MB cache module
CAUTION: To avoid damage to the controller board, only install the cache module when the
HP Smart Array P700m/512 Controller is installed in the server blade.
IMPORTANT: If you need to remove the cache module to transfer data, the BBWC battery must
remain connected to it so that the data is preserved. If possible, HP recommends that you install
the P700m into slot 3 so that the cache and battery can be removed together.
1. Power down the server blade and remove it from the server blade enclosure (“Preparing
the server blade for servicing”).
2. Remove the access panel (“Removing the server blade access panel”).
3. Remove the DIMM baffle (“Removing the DIMM baffle”)
106 HP Smart Array P700m/512 Controller