Specifications
Table Of Contents
- HP Integrity BL860c Server Blade User Service Guide
- Contents
- About This Document
- 1 Overview
- 2 General Site Preparation Guidelines
- 3 Installing the Server Blade Into the Enclosure
- Safety Information
- Installation Sequence and Checklist
- Unpacking and Inspecting the Server Blade
- Installing Additional Components
- Installing and Powering On the Server Blade
- Accessing the Integrated Lights Out 2 Management Processor
- Configuring the iLO 2 MP
- Accessing EFI or the OS from iLO 2 MP
- Server Blade to Enclosure Interface
- LAN / NIC Configuration
- Configuring the HP 2 Internal Port SAS Host Bus Adapter
- Verify and Install the Latest Firmware
- 4 Booting and Shutting Down the Operating System
- 5 Troubleshooting
- Methodology
- Troubleshooting Tools
- Errors and Error Logs
- Supported Configurations
- Troubleshooting Processors/Memory/SBA
- Enclosure Information
- Cooling Subsystem
- Troubleshooting Communications Modules
- Troubleshooting Management Subsystem
- Firmware
- Troubleshooting the Server Interface (System Console)
- Troubleshooting the Environment
- Reporting Your Problems to HP
- 6 Removing and Replacing Components
- Service Tools Required
- Removing and Replacing a Hot-Plug SAS Disk Drive
- Preparing the Server Blade for Servicing
- Removing and Replacing the Server Blade from the Enclosure
- Removing and Replacing the Server Blade Access Panel
- Removing and Replacing Internal Components
- Removing and Replacing DIMMs
- Removing and Replacing a Processor
- Removing and Replacing the SAS Backplane
- Removing and Replacing the Front Display Assembly
- Removing and Replacing the Server Battery
- Removing and Replacing the Mezzanine Cards
- Removing and Replacing a Cache Module
- Removing and Replacing the Low Profile Battery Backed Write Cache (BBWC) Battery
- Removing and Replacing the Trusted Platform Module
- Removing and Replacing the System Board
- A Parts Information
- B Server Upgrades
- C Utilities
- NVRAM Backup Utility
- Extensible Firmware Interface
- EFI/POSSE Commands
- Specifying Parameters
- Using the Boot Option Maintenance Menu
- Integrated Lights Out 2 Management Processor
- Index

Example 19 ioconfig command
Shell> ioconfig
Deconfigure or reconfigure IO components or settings
IOCONFIG [fast_init | wol [on | off]]
fast_init Specifies device connection policy setting
mps_optimize Specifies PCIe optimization setting
wol Specifies System Wake-On-LAN setting
on | off Specifies to configure or deconfigure a feature or component
Note:
1. If fast_init is enabled, firmware will connect only the minimum set of
devices during boot. This feature might cause boot failure; disable this
feature if failure occurs.
2. A reboot is required for PCIe MPS optimization changes to take effect
3. Any pending Wake-On-LAN request will not be cleared until reboot if
the setting is changed to disabled.
System will clear pending Wake-On-LAN requests each time the system
reboots if the setting is disabled.
Examples:
* To display the current settings
fs0:\> ioconfig
Fast initialization: Enabled
MPS optimization: Disabled
System Wake-On-LAN: Disabled
* To display the current device connection policy setting
fs0:\> ioconfig fast_init
Fast initialization: Enabled
* To disable fast initialization
fs0:\> ioconfig fast_init off
Fast initialization: Disabled
* To enable the System Wake-On-LAN setting
fs0:\> ioconfig wol on
System Wake-On-LAN: Enabled
lanaddress
Enables you to display the core I/O MAC address.
Syntax:
lanaddress
Parameters
none
Example 20 lanaddress Command
LAN Address Information:
LAN Address Path
----------------- ----------------------------------------
Mac(00306E4C4F1A) Acpi(HWP0002,0)/Pci(3|0)/Mac(00306E4C4F1A))
*Mac(00306E4C0FF2) Acpi(HWP0002,100)/Pci(2|0)/Mac(00306E4C0FF2))
monarch
Displays or modifies the ID of the bootstrap processor. The preferred monarch number is stored in
NVM.
166 Utilities