Specifications
Table Of Contents
- HP Integrity BL860c Server Blade User Service Guide
- Contents
- About This Document
- 1 Overview
- 2 General Site Preparation Guidelines
- 3 Installing the Server Blade Into the Enclosure
- Safety Information
- Installation Sequence and Checklist
- Unpacking and Inspecting the Server Blade
- Installing Additional Components
- Installing and Powering On the Server Blade
- Accessing the Integrated Lights Out 2 Management Processor
- Configuring the iLO 2 MP
- Accessing EFI or the OS from iLO 2 MP
- Server Blade to Enclosure Interface
- LAN / NIC Configuration
- Configuring the HP 2 Internal Port SAS Host Bus Adapter
- Verify and Install the Latest Firmware
- 4 Booting and Shutting Down the Operating System
- 5 Troubleshooting
- Methodology
- Troubleshooting Tools
- Errors and Error Logs
- Supported Configurations
- Troubleshooting Processors/Memory/SBA
- Enclosure Information
- Cooling Subsystem
- Troubleshooting Communications Modules
- Troubleshooting Management Subsystem
- Firmware
- Troubleshooting the Server Interface (System Console)
- Troubleshooting the Environment
- Reporting Your Problems to HP
- 6 Removing and Replacing Components
- Service Tools Required
- Removing and Replacing a Hot-Plug SAS Disk Drive
- Preparing the Server Blade for Servicing
- Removing and Replacing the Server Blade from the Enclosure
- Removing and Replacing the Server Blade Access Panel
- Removing and Replacing Internal Components
- Removing and Replacing DIMMs
- Removing and Replacing a Processor
- Removing and Replacing the SAS Backplane
- Removing and Replacing the Front Display Assembly
- Removing and Replacing the Server Battery
- Removing and Replacing the Mezzanine Cards
- Removing and Replacing a Cache Module
- Removing and Replacing the Low Profile Battery Backed Write Cache (BBWC) Battery
- Removing and Replacing the Trusted Platform Module
- Removing and Replacing the System Board
- A Parts Information
- B Server Upgrades
- C Utilities
- NVRAM Backup Utility
- Extensible Firmware Interface
- EFI/POSSE Commands
- Specifying Parameters
- Using the Boot Option Maintenance Menu
- Integrated Lights Out 2 Management Processor
- Index

boottest off Skip all tests (for a faster boot time)
boottest [test] Displays status of specific Speedy Boot bit
boottest [test] [on|off] Sets or clears a specific Speedy Boot bit
Parameters
[test] Each test can be set or cleared:
booting_valid Enable/disable system firmware response to BOOTING
bit. If OS Speedy Boot aware set to on.
early_cpu Enable/disable early CPU selftests.
late_cpu Enable/disable late CPU selftests.
platform Enable/disable system board hardware tests.
chipset Enable/disable CEC tests.
io_hw Enable/disable EFI driver Core I/O tests.
mem_init Enable/disable memory initialization.
mem_test Enable/disable full destructive memory tests.
Example 6 boottest Command
Shell> boottest
BOOTTEST Settings Default Variable
Selftest Setting
------------- -------------------------
booting_valid On (OS speedy boot aware)
early_cpu Run this test
late_cpu Run this test
platform Run this test
chipset Run this test
io_hw Run this test
mem_init Run this test
mem_test Run this test
Example 7 boottest early_cpu off Command
Shell> boottest early_cpu off
BOOTTEST Settings Default Variable
Selftest Setting
------------- -------------------------
booting_valid On (OS speedy boot aware)
early_cpu Skip this test
late_cpu Run this test
platform Run this test
chipset Run this test
io_hw Run this test
mem_init Run this test
mem_test Run this test
cpuconfig
Use this command to display the configured or deconfigured state of processors in the server. This
command also enables you to configure or reconfigure processors.
Syntax
cpuconfig <cpu> <on|off>
Parameters
<cpu> specify a processor
<on|off> state to set the processor to
Operation
Issuing cpuconfig with no parameters displays the config/deconfig status of all processors. A
user can reconfigure processors by specifying a processor number and a state (on or off). If a valid