Specifications
Table Of Contents
- HP Integrity BL860c Server Blade User Service Guide
- Contents
- About This Document
- 1 Overview
- 2 General Site Preparation Guidelines
- 3 Installing the Server Blade Into the Enclosure
- Safety Information
- Installation Sequence and Checklist
- Unpacking and Inspecting the Server Blade
- Installing Additional Components
- Installing and Powering On the Server Blade
- Accessing the Integrated Lights Out 2 Management Processor
- Configuring the iLO 2 MP
- Accessing EFI or the OS from iLO 2 MP
- Server Blade to Enclosure Interface
- LAN / NIC Configuration
- Configuring the HP 2 Internal Port SAS Host Bus Adapter
- Verify and Install the Latest Firmware
- 4 Booting and Shutting Down the Operating System
- 5 Troubleshooting
- Methodology
- Troubleshooting Tools
- Errors and Error Logs
- Supported Configurations
- Troubleshooting Processors/Memory/SBA
- Enclosure Information
- Cooling Subsystem
- Troubleshooting Communications Modules
- Troubleshooting Management Subsystem
- Firmware
- Troubleshooting the Server Interface (System Console)
- Troubleshooting the Environment
- Reporting Your Problems to HP
- 6 Removing and Replacing Components
- Service Tools Required
- Removing and Replacing a Hot-Plug SAS Disk Drive
- Preparing the Server Blade for Servicing
- Removing and Replacing the Server Blade from the Enclosure
- Removing and Replacing the Server Blade Access Panel
- Removing and Replacing Internal Components
- Removing and Replacing DIMMs
- Removing and Replacing a Processor
- Removing and Replacing the SAS Backplane
- Removing and Replacing the Front Display Assembly
- Removing and Replacing the Server Battery
- Removing and Replacing the Mezzanine Cards
- Removing and Replacing a Cache Module
- Removing and Replacing the Low Profile Battery Backed Write Cache (BBWC) Battery
- Removing and Replacing the Trusted Platform Module
- Removing and Replacing the System Board
- A Parts Information
- B Server Upgrades
- C Utilities
- NVRAM Backup Utility
- Extensible Firmware Interface
- EFI/POSSE Commands
- Specifying Parameters
- Using the Boot Option Maintenance Menu
- Integrated Lights Out 2 Management Processor
- Index

Figure 43 ZIF Socket on the Processor
8. Carefully remove the processor module by lifting it straight up from the system board.
9. Place the processor module in an antistatic bag.
Installing a Processor
To install the processor:
1. Ensure the ZIF socket for the processor you are installing is open.
Insert the 2.5 mm hex end of the Torx T-15 screwdriver into the ZIF socket and gently try to
rotate the socket 180 degrees counter clockwise. If the socket doesn’t turn, the socket is open.
See Figure 44 (page 117).
NOTE: If you have just removed a processor, the ZIF socket is unlocked.
Figure 44 ZIF Socket Unlocked
2. Carefully insert the processor module into the empty processor slot (processor slot 0 is shown)
on the server blade system board; then line up the guide pins on the processor to the alignment
holes in the processor slot to seat the processor.
See Figure 45 for the alignment hole locations for processor slot 0.
Removing and Replacing a Processor 117