Specifications
Table Of Contents
- HP Integrity BL860c Server Blade User Service Guide
- Contents
- About This Document
- 1 Overview
- 2 General Site Preparation Guidelines
- 3 Installing the Server Blade Into the Enclosure
- Safety Information
- Installation Sequence and Checklist
- Unpacking and Inspecting the Server Blade
- Installing Additional Components
- Installing and Powering On the Server Blade
- Accessing the Integrated Lights Out 2 Management Processor
- Configuring the iLO 2 MP
- Accessing EFI or the OS from iLO 2 MP
- Server Blade to Enclosure Interface
- LAN / NIC Configuration
- Configuring the HP 2 Internal Port SAS Host Bus Adapter
- Verify and Install the Latest Firmware
- 4 Booting and Shutting Down the Operating System
- 5 Troubleshooting
- Methodology
- Troubleshooting Tools
- Errors and Error Logs
- Supported Configurations
- Troubleshooting Processors/Memory/SBA
- Enclosure Information
- Cooling Subsystem
- Troubleshooting Communications Modules
- Troubleshooting Management Subsystem
- Firmware
- Troubleshooting the Server Interface (System Console)
- Troubleshooting the Environment
- Reporting Your Problems to HP
- 6 Removing and Replacing Components
- Service Tools Required
- Removing and Replacing a Hot-Plug SAS Disk Drive
- Preparing the Server Blade for Servicing
- Removing and Replacing the Server Blade from the Enclosure
- Removing and Replacing the Server Blade Access Panel
- Removing and Replacing Internal Components
- Removing and Replacing DIMMs
- Removing and Replacing a Processor
- Removing and Replacing the SAS Backplane
- Removing and Replacing the Front Display Assembly
- Removing and Replacing the Server Battery
- Removing and Replacing the Mezzanine Cards
- Removing and Replacing a Cache Module
- Removing and Replacing the Low Profile Battery Backed Write Cache (BBWC) Battery
- Removing and Replacing the Trusted Platform Module
- Removing and Replacing the System Board
- A Parts Information
- B Server Upgrades
- C Utilities
- NVRAM Backup Utility
- Extensible Firmware Interface
- EFI/POSSE Commands
- Specifying Parameters
- Using the Boot Option Maintenance Menu
- Integrated Lights Out 2 Management Processor
- Index

4. On the server blade you are updating, issue the fweupdate.efi command from the EFI
command prompt by entering: fweupdate.BL860c.sxxxx.byyyy.mzzzz.efi.
where:
s means system firmware; xxxx is the system firmware version number
b means BMC firmware; yyyy is the BMC firmware version number
m means iLO 2 MP firmware; zzzz is the iLO 2 MP firmware version number
This command updates the system firmware, BMC firmware, and iLO 2 MP firmware.
Troubleshooting the Server Interface (System Console)
All system console connections (local RS-232 and iLO 2 MP LAN) are made through the I/O port
connector on the front of the server blade, through the local I/O cable.
HP-UX uses the RS-232 serial text connection to a dumb terminal, or to terminal emulator software
running on a PC, to control server blade operations locally. All other connections are unsupported.
HP-UX alternatively uses the MP’s 10/100 BT LAN connection over a private network, to control
one or more server blade operations -- locally through telnet or Secure Shell (SSH), or remotely
over a public network through a web GUI.
NOTE: RS-232 connection: If a dumb terminal/PC running terminal emulation software is attached
to the iLO 2 MP local port and does not respond to a Ctrl-B key sequence (and the terminal is
running 9600 baud, 8 data bits, is online, etc.) then it is possible that the iLO 2 MP is not
operational/functional.
Troubleshooting the Environment
Ambient intake air temperature is often different from ambient room temperature; measure the
operating temperature and humidity directly in front of the cabinet cooling air intakes, rather than
measure only ambient room conditions.
Within the server blade enclosure, temperature sensors report chassis temperature to the BMC.
The BMC controls fan speed, based on this information.
Temperature sensors are found on:
• I/O baseboard, where the processors provide an integrated temperature sensor
• Status panel, where a thermal sensor detects the ambient room temperature. This sensor’s
reading is the main parameter used to regulate fan speed, under normal conditions.
Table 27 provides environmental specifications for server blades:
Table 27 Blade Server Environmental Specifications
Non-Operating RangeMaximum Rate of ChangeRecommended
Operating Range
Operating RangeParameter
-40 degrees to +60
degrees C
10 degrees C/hr with
tape; 20 degrees C/hr
without tape
20-25 degrees C (up
to 5000 feet)
5-35 degrees C (up to
5000 feet)
Temperature
90% at 65 degrees C
noncondensing
30% per hour
noncondensing
40-60% at 35 degrees
C noncondensing
15-80% at 35 degrees
C noncondensing
Relative Humidity
Reporting Your Problems to HP
HP customer care will help you solve server blade problems and, if necessary, initiate appropriate
service procedures. Support is available on the web and by phone.
For information on contacting the HP Support Center (HPSC) near you, go to: http://www.hp.com/
go/hpsc.
106 Troubleshooting