User's Manual
Upgrading to Instant Capacity version B.06.x or later (HP-UX)
The first time a version of the codeword-based B9073BA Instant Capacity software (B.06.00 or
later) is loaded onto a system where the old B9073AA software (version B.03.x through B.05.x)
has been in use, the new software requires the system to go through an upgrade process.
This process involves transferring Instant Capacity inventory information from HP to the system
through the application of an upgrade codeword. This allows the system (using the B9073BA
software) to keep track of the number of components without usage rights.
Prior to December 2003, the Instant Capacity software product (B9073AA) was loaded from
Support Plus media and was not present on the 11i v1 and 11i v2 Operating Environment (OE)
media. In December 2003, an updated version of the Instant Capacity software product (B9073BA)
was placed on the 11i v1 and 11i v2 OE media.
The Instant Capacity version B.09.x software (B9073BA) is automatically installed when the
HP-UX 11i v3 OE is installed. When a newer version of the HP-UX OE is installed in a partition,
the Instant Capacity software in the OE is automatically updated in that partition.
After the Instant Capacity software is updated in one partition from an older B9073AA version
(B.03.x through B.05.x) to the newer B9073BA version (B.06.00 or later), the Instant Capacity
software in all of the system’s other partitions needs to be updated before the new software is
completely operational. Until that time, the new software does not have visibility of the status
of partitions running the old software. As a result, it is likely that exception email will be generated
daily from the new software until all updates are completed.
After the installation of new Instant Capacity B9073BA software on the first partition, perform
the following steps.
NOTE: The following HP-UX procedures use the obsolete commands, such as icod_stat and
icod_modify, because these commands are common to all versions of Instant Capacity (B.06.x,
or later). On version B.09.x, these commands could be icapstatus or icapmodify, which
have identical results.
1. Execute the following command and record the output:
/usr/sbin/icod_stat -s
You can copy and paste the output of the icod_stat -s command and save it in a text
file. You need this information later in step 4.
2. Go to the HP Utility Pricing Solutions web portal at http://www.hp.com/go/icap/portal. Log
in to the portal and click the link to get codewords.
3. Click the Upgrade Codeword link to get an upgrade codeword.
4. Supply the requested information from the icod_stat -s command output gathered in
step 1, and get the upgrade codeword from the portal. You need the codeword in the next
step.
5. Apply the upgrade codeword, generated by the Utility Pricing Solutions portal, to the system
by executing this command:
/usr/sbin/icod_modify -C codeword
where codeword is the upgrade codeword that was supplied by the portal in step 4. This
is easily accomplished by copying and pasting the codeword (that is generated by the portal)
to the system where you are executing the icod_modify -C codeword command. The
upgrade codeword needs to be applied only once on the entire system.
6. Install or upgrade all other partitions with the Instant Capacity B9073BA software (version
B.06.00 or later). This software is on the 11i v1, 11i v2 and 11i v3 OE media, starting with the
December 2003 media, and is automatically installed when the 11i v1, 11i v2, or 11i v3 OE
is installed. The software is also available from the HP web site at http://www.hp.com/go/
softwaredepot (search for B9073BA). If you do not complete this step, in the absence of other
information, the Instant Capacity software assumes that all partitions that were not upgraded
are fully active. If all partitions in a system are not upgraded, the Instant Capacity software
might determine the system to be in an exception state.
Upgrading to Instant Capacity version B.06.x or later (HP-UX) 193