Installing HP Insight Software 6.1 Update 1 on Windows Server 2008 R2 Failover Clusters with SQL Server 2008 for high availability

45
a.
Browse to VCRM using the
Systems Insight Manager
virtual network name and port
2381, for
example
https://cms
-
hpsim.fqdn:2381
. Login with the same credentials used in Step 1.
b.
On the
bottom of the SMH home page, click
Version Control Repository Manager
. The
Version
Control Repository Manager
home page appears.
c.
On the right end of the gray navigation bar
,
just below the
Home
tab
,
click
Change repository
& update settings
.
d.
Enter the path to the folder created in Step 2 above. Click
Next
.
e.
Select
Windows Server 2008 R2
for the operating system and
then
click
Next
.
f.
Set the automatic update settings as desired. Click
Finish
and
Close
.
Insight Control power management
For certain managed power devices, such as HP PDUs that communicate with
Systems Insight
Manager
over SNMP and that restrict access to specified hosts, their configuration
must
include the IP
addresses of both the primary and secondary CMS systems
.
U
sing t
he
Systems Insight Manager
virtual server IP address does not work with these devices.
Insight Control server migration
To ensure correct operation of HP Insight Control server migration in a highly available CMS
environment on a Windows Server 2008 R2 sys
tem,
o
n the Insight Software shared disk, in this white
paper drive
V:
\
, edit the file
<SMP install dir>
\
bin
\
windows
\
hpmmsvc.conf:
At the end of th
e section starting
# Java Additional Parameters
and above
# Initial Java Heap Size
,
add the line in
green
ita
lic
:
# Java Additional Parameters
...
wrapper.java.additional.4=
-
DmountDir=c:
\
windows
\
temp
# Initial Java Heap Size (in MB)
wrapper.java.initmemory=16
The two lines preceding the line
to be
add
ed
should
begin with the
#
character, indicating they are
comments:
# wrapper.java.additional.4= …
# wrapper.java.additional.5=
After the configuration file change is done, save the file. In
Failover Cluster Manager
, take the
HP
Insight Control server migration Application Servi
ce
and the
HP Insight Control server migration Web
Service
resources
offline and
t
hen bring both resources back online.
Global Workload Manager (gWLM)
1.
Add the following property to the gWLM Agent property file found in
~
\
Virtual Server
Environment
\
conf
\
gwl
magent.properties:
com.hp.gwlm.security.virtualLocalHostName=SIMvirtualserverIP
Where
SIMvirtualserverIP
is the virtual server IP address of
Systems Insight Manager
.
2.
In
Failover Cluster Manager
, take the
HP
Systems Insight Manager
and the
HP
Global
workload
Manager Central Management System
resources
offline and t
hen bring both resources back online.
Insight Dynamics infrastructure orchestration