Installing and upgrading to HP Insight Software 6.2 on Windows Server 2003 R2 MSCS for high availability
41
Appendix A:
Upgrading clustered Insight Software
T
his appendix
des
c
r
ibes h
o
w to
u
pgrade
Insight
Sof
tw
are to the 6
.
2 relea
s
e in
a
two
-
system
c
l
u
s
t
er.
It also in
c
l
u
d
es
steps
f
or inst
a
lling
n
e
w fea
t
u
r
e
s as a
part
of
u
pgradin
g.
T
h
e
following
u
p
grade paths have been
tes
t
ed:
Insight
S
o
ftw
a
re 3
.
1 to 6
.
1
Insight
S
o
ftw
a
re 6
.
0 to 6
.
1
Insight
S
o
ftw
a
re 6
.
1 to 6
.
2
This appendix documents how to upgrade from 6.1 to 6.2. See
Installing and upgrading to HP
Insight Software 6.1 on Windows Server 2003 R2 MSCS for high availability
for instructions on
upgrading from 3.1 to 6.1 and 6.0 to 6
.1.
Upgrade overview
T
he f
o
ll
o
wing
steps are a
h
i
gh
level o
v
er
v
iew
o
f the
u
p
grade pro
c
e
d
u
re
f
or In
s
ight
Software r
u
n
ning
in
a
tw
o
-
system
MSCS
c
l
u
s
t
e
r
.
For details,
see the s
ec
tion,
Upgrade steps
bel
o
w.
A.
Back up the cluster including the Insight Software and
SQL Server shared disks.
B.
Install any
prereq
u
i
si
t
e s
o
f
t
ware for HP
I
nsight Sof
t
ware 6
.
2 on
both
c
l
u
ster
system
s.
C.
Upgrade the primary system.
Ensure the secondary system is shutdown.
After
r
emovi
n
g Insight
S
o
ftware
s
erv
i
c
e
s
from
c
l
u
s
t
er
c
ontrol,
r
u
n
A
d
minis
t
rati
v
e
T
ools
-
Ser
v
i
c
es
to start the In
s
ight
Softwa
r
e serv
i
c
e
s on
t
h
e primary system.
Upgrade the primary system to the new Insight Software version.
D.
Restore the Insight Software and SQL shared disks to their pre
-
upgrade state.
E.
Upgrade the secondary system
.
Ensure the primary system is shutdown.
After
r
emovi
n
g Insight
S
o
ftware
s
erv
i
c
e
s
from
c
l
u
s
t
er
c
ontrol,
r
u
n
A
d
ministrati
v
e
T
ool
s
Ser
v
i
c
es
to start the In
s
ight
Softwa
r
e serv
i
c
e
s on
t
h
e s
e
c
ondary system.
Upgrade the s
e
c
ondary
to the new In
s
ig
h
t
Software ve
r
sion.
Stop
the Insi
g
ht
Software
se
rvi
c
e
s on
the
s
e
c
ondary system.
F.
Use C
l
u
s
t
er
A
dministrator
t
o
u
pdate
c
l
u
s
t
er r
e
so
u
r
c
es
f
or the new
so
ftware r
e
lea
se.
G.
Start HP Systems Ins
i
ght
M
a
nager (Systems Insight Manager)
o
n
the
p
rimary system.
H.
Per
f
orm
validation
and
f
inal
c
onf
i
g
u
rati
o
n
s
tep
s
.
NOTE:
T
he
Insight
S
o
ft
w
are
installer
stops
and
starts
the
I
ns
ight S
o
ftware
se
r
vices.
Before
runni
n
g
t
h
e instal
l
er,
you
m
ust
ta
k
e
the
I
n
si
g
ht
So
f
tware
(
C
M
S
-
HA)
cluster
group
of
f
l
i
ne
so that
M
S
CS is
not
monitori
n
g
the
services.
Y
o
u
do
not need to
ta
k
e
offl
i
ne
the
S
Q
L
S
erver
(S
Q
L)
c
l
ust
e
r
group
or
any other
cluster
group.
For
details,
refer
to
t
he
s
e
ction,
U
p
g
r
ade
steps
belo
w.