Installing and upgrading to HP Insight Software 6.0 on Windows Server 2003 R2 MSCS for high availability

21
10. Click Finish to complete the configuration. A summary window appears.
Optionally, click Test Data Source to validate the connection.
11. Click OK. The ODBC Data Source Administrator window appears.
12. Click OK to close the ODBC Data Source Administrator window.
Figure 8: Retarget the data source name on the primary system
Add
the Insight software cluster resources
To complete the installation of HP Insight Software to the cluster, several cluster resources must be
created using Cluster Administrator. This can be accomplished either manually or by running the
CMS-HA configuration scripts found in
Appendix A
.
1. Power the primary system on, and log in to Windows as Administrator.
2. Power the secondary system on.
3. Open the Cluster Administrator tool from the primary system and confirm that the primary system
owns all the cluster resources. Ensure that the Cluster Service is running on the secondary system
(select the Start Cluster Service menu option if it is not running).
4. The CMS-HA Group and the CMS-HA Disk resource were created before Insight software was
installed. Clicking on Groups in the Cluster Administrator should show: